{"postcode":"IG11 0HZ","status":"Approved","decision_agency":null,"subdivision_of_building":null,"appeal_start_date":null,"cil_liability":null,"decision_conditions":["The development hereby permitted shall be commenced before the expiration of three years from the date of this permission.<br>","<p>The development hereby approved shall only be carried out in accordance with the following approved plans and documents:</p><p>- TR-0112-EPP 1/1 Existing and Proposed Plans 1/12/2025<br>- TR-1501-PBP Existing and Proposed Block Plan 15/01/2025&nbsp;<br>- Site Location Plan 14 October 2024</p><p>No other drawings or documents apply.</p>","\r\n Noise Generating Mechanical Services Plant . Before any\r\n     mechanical services plant including heating, ventilation, and air\r\n     conditioning (HVAC) and refrigeration plant, &nbsp;to which the\r\n     application refers, is used at the premises, a scheme shall be submitted\r\n     to and approved in writing by the Local Planning Authority (LPA) which is\r\n     in accordance with the details provided in &nbsp;the Environmental Noise\r\n     Impact Assessment Report dated 20/12/2025 by Ron-Berks Acoustic Limited.\r\n     As a minimum any scheme must demonstrate that the following noise design requirements\r\n     can be complied with. \r\n&nbsp;\r\n The cumulative measured or calculated rating level of noise\r\n     emitted from the mechanical services plant to which the application\r\n     refers, shall be lower than the existing background noise level by 10dB\r\n     at all times when the plant is in operation.Measurements shall be made at a height of 1.2 – 1.5 metres above the\r\nadjacent ground level and at least 3.5 metres from any sound reflecting\r\nsurfaces other than the ground or 1 metre from the facade of the nearest first floor\r\n(or higher) noise sensitive premises, and in accordance with the latest British\r\nStandard BS4142:2014.The measurement value shall be adjusted to remove the additional sound\r\nenergy contribution from reflected surfaces other than from the ground.An alternative position for assessment /measurement may be used to allow\r\nease of access, this must be shown on a map and noise propagation calculations\r\ndetailed to show how the design criteria is achieved.&nbsp;The\r\napproved scheme shall thereafter be maintained.&nbsp;\r\n At all times the plant shall be isolated to ensure that\r\n     vibration amplitudes which cause re-radiated noise do not exceed the\r\n     limits detailed in table 4 in section 7.7.2 of BS8233:2014 “Guidance on\r\n     sound insulation and noise reduction for buildings”. Alternatively, the\r\n     plant shall be supported on adequate proprietary anti-vibration mounts to\r\n     reduce the structural transmission of vibration and regenerated noise\r\n     within adjoining premises, and these shall be maintained thereafter.\r\n&nbsp;\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n &nbsp;A commissioning acoustic test and report shall be\r\n     undertaken within 7 days of mechanical services commissioning in order to\r\n     demonstrate that conditions a) and b) &nbsp;&nbsp;above have been\r\n     achieved. The results of the test shall be submitted to and approved in\r\n     writing by the LPA.\r\n"],"actual_commencement_date":null,"pp_id":null,"decision_target_date":"16/03/2026","valid_date":"19/01/2026","lpa_app_no":"26/00074/FULL","locality":null,"appeal_decision_date":null,"parking_details":null,"decision_process":null,"street_name":"THAMES ROAD","last_synced":"2026-04-16T03:04:03.336Z","site_number":null,"centroid_easting":null,"polygon":{"crs":{"properties":{"name":"EPSG:27700"},"type":"name"},"geometries":[{"coordinates":[[[545831.400889528,182777.299514949],[545831.087202282,182763.16697972],[545851.003727581,182762.962866494],[545851.300889538,182776.799514954],[545837.364849609,182777.149658531],[545831.400889528,182777.299514949]]],"type":"Polygon"}],"type":"geometrycollection"},"ward":"Thames View","centroid_northing":null,"application_type":"All Other","uprn":null,"lapsed_date":"05/03/2029","actual_completion_date":null,"decision":"Approved","site_name":"Unit Nr1, 12","borough":"London Borough of Barking and Dagenham","last_date_consultation_comments":"19/02/2026","application_type_full":null,"url_planning_app":"https://online-befirst.lbbd.gov.uk/planning/index.html?fa=getApplication&id=37118","decision_date":"05/03/2026","bo_system":"Portal","development_type":"Minor all other minor developments","appeal_status":null,"date_building_work_completed_under_previous_permission":null,"description":"Installation of 6no external AC condenser units","appeal_decision":null,"date_building_work_started_under_previous_permission":null,"epc_number":null,"last_updated":"2026-04-15T11:20:10.206Z","centroid":{"lon":-7.55716,"lat":49.766807},"lpa_name":"Barking & Dagenham","secondary_street_name":null,"application_details":{},"wgs84_polygon":{"coordinates":[[[0.100737,51.525086],[0.100726,51.52496],[0.101013,51.524953],[0.101023,51.525077],[0.100823,51.525084],[0.100737,51.525086]]],"type":"Polygon"},"id":"Barking_&_Dagenham-26_00074_FULL","reference_no_of_permission_being_relied_on":null,"title_number":null,"last_updated_by":"Portal"}