{"borough":"Hackney","application_type":"All Other","decision":null,"decision_conditions":["&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;No development (including site clearance, soil stripping, or the delivery of plant and materials) shall commence until a finalised site-specific Arboricultural Method Statement (AMS) and Tree Protection Plan (TPP) have been submitted to and approved in writing by the Local Planning Authority. These documents must strictly adhere to the recommendations set out in the approved Arboricultural Impact Assessment for 139 Blackstock Road, London (Ref: 12194-D-AIA) and comply with BS 5837:2012.&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;The submitted details must include:&lt;/span&gt;&lt;/p&gt;&lt;ul style=&quot;margin-top:0;margin-bottom:0;padding-inline-start:48px;&quot;&gt;&lt;li dir=&quot;ltr&quot; style=&quot;list-style-type:disc;font-size:11pt;font-family:Arial,sans-serif;color:#222222;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;&quot; aria-level=&quot;1&quot;&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot; role=&quot;presentation&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Tree Protection Barriers: Detailed plans for the placement of protective fencing to establish construction exclusion zones around the re-calculated Root Protection Areas (RPA) of trees T001 and T002.&lt;/span&gt;&lt;/p&gt;&lt;/li&gt;&lt;li dir=&quot;ltr&quot; style=&quot;list-style-type:disc;font-size:11pt;font-family:Arial,sans-serif;color:#222222;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;&quot; aria-level=&quot;1&quot;&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot; role=&quot;presentation&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Foundation Engineering: Specific methodologies and engineering drawings for the cantilevered foundation design and any specialist construction required to accommodate the RPAs, as identified on the Proposed Site Plan.&lt;/span&gt;&lt;/p&gt;&lt;/li&gt;&lt;li dir=&quot;ltr&quot; style=&quot;list-style-type:disc;font-size:11pt;font-family:Arial,sans-serif;color:#222222;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;&quot; aria-level=&quot;1&quot;&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot; role=&quot;presentation&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Specifications for the design of brick built raised planting beds within RPAs of retained trees as designed by a Structural Engineer, in conjunction with an Arboriculturalist. To include specialised foundations (e.g. piled, micro piled, or&lt;/span&gt;&lt;/p&gt;&lt;/li&gt;&lt;li dir=&quot;ltr&quot; style=&quot;list-style-type:disc;font-size:11pt;font-family:Arial,sans-serif;color:#222222;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;&quot; aria-level=&quot;1&quot;&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot; role=&quot;presentation&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;pad and beam) where the footprint of the structure coincides with the RPA.Additionally, any ground beam or similar structural support placed to span piles or pads must be above, and so not cut into, the existing ground level when within&lt;/span&gt;&lt;/p&gt;&lt;/li&gt;&lt;li dir=&quot;ltr&quot; style=&quot;list-style-type:disc;font-size:11pt;font-family:Arial,sans-serif;color:#222222;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;&quot; aria-level=&quot;1&quot;&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot; role=&quot;presentation&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;the RPA.&lt;/span&gt;&lt;/p&gt;&lt;/li&gt;&lt;li dir=&quot;ltr&quot; style=&quot;list-style-type:disc;font-size:11pt;font-family:Arial,sans-serif;color:#222222;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;&quot; aria-level=&quot;1&quot;&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot; role=&quot;presentation&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Surface Works: A sequence of operations for removing existing hard surfacing to revert to soft landscape and for &#x27;No-dig&#x27; methodology for new surfaces within RPAs.&lt;/span&gt;&lt;/p&gt;&lt;/li&gt;&lt;li dir=&quot;ltr&quot; style=&quot;list-style-type:disc;font-size:11pt;font-family:Arial,sans-serif;color:#222222;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;&quot; aria-level=&quot;1&quot;&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot; role=&quot;presentation&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Facilitation Pruning: A precise schedule for the crown reduction required for trees to facilitate the prospective development.&lt;/span&gt;&lt;/p&gt;&lt;/li&gt;&lt;/ul&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-9a4ca828-7fff-240f-d192-69f4a3a11364&quot;&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: To safeguard existing tree(s) in the interests of visual amenity, having regard to Policy LP51 in the Local Plan 2033 (adopted 2020) and pursuant to Section 197 of the Town and Country Planning Act 1990.&lt;/span&gt;&lt;/p&gt;","&lt;p&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, sans-serif; white-space-collapse: preserve; text-align: justify;&quot;&gt;Prior to commencing the works, for each section of the development or stage in the development - as may be agreed in writing by the Local Planning Authority (LPA) - a scheme including the following components to address the risks associated with site contamination shall be submitted to, and approved in writing by, the LPA.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;b style=&quot;font-weight:normal;&quot;&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;a) A preliminary risk assessment which identifies all previous uses, potential contaminants associated with those uses (including asbestos, landfill gas, vapours and ground water contaminants); a conceptual model of the site indicating sources, pathways and receptors; and potentially unacceptable risks arising from contamination at the site;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;b) A generic and detailed quantitative risk assessment based on (a) that identifies the risk to all receptors potentially affected, including those off site;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;c) In the event that remediation measures are deemed necessary following the results of (b), an options appraisal identifying feasible remediation options, detailing evaluation of options, and selecting the most appropriate remediation option(s);&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;d) A remediation strategy focused on the remediation option(s) selected in (c) setting site specific monitoring objectives and criteria, providing details of monitoring and maintenance, and containing full details of the remediation measures required, and how they are to be undertaken.&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;e) A verification plan explaining how the effectiveness of the remediation works set out in (d) will be measured, and how data will be collected and assessed to demonstrate that the remediation objectives and criteria will be met.&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;f) A verification report demonstrating that remediation objectives and criteria identified in (e) have been met, assessing the remediation performance, and creating a final record of the land quality whilst providing a plan for long term monitoring and maintenance (if required).&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;b style=&quot;font-weight:normal;&quot;&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Any investigation and risk assessment must be undertaken in strict accordance with the requirements of the Environment Agency’s Land Contamination Risk Management (LCRM).&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;If additional significant contamination is found at any time when carrying out the approved development, it must immediately be reported in writing to the LPA.&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;For the avoidance of doubt, this condition can be discharged on a section by section basis.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: rgb(255, 255, 255); font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: To protect human health and the environment by ensuring no harm is caused by land contamination, in line with paragraphs H, I and J, LP 58 of the Hackney Local Plan 2033 and the Hackney contaminated land strategy 2022/2030.&lt;/span&gt;&lt;/p&gt;","<p>The Development hereby permitted shall only be carried out and completed strictly in accordance with the submitted plans hereby approved and any subsequent approval of details.\r\n</p><p><br></p><p>\r\nREASON: To ensure that the development hereby permitted is carried out in full accordance with the plans hereby approved.\r\n</p>","<p>The development hereby permitted must be begun not later than the expiration of three years beginning with the date of this permission.</p><p><br></p><p>\r\n</p><p>\r\nREASON: In order to comply with the provisions of the Town and Country Planning Act 1990 (as amended).</p><p>\r\n</p>","&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Prior to superstructure works, detailed specification, a drainage layout and a management &amp;amp; maintenance plan (where applicable) of at least one suitable sustainable drainage system (i.e. water butt with overflow, raingarden, bioretention planter box, living roof (substrate depth of 80-150mm excluding the vegetative mat), permeable paving etc.) shall be submitted to, and approved by the LPA, in consultation with the LLFA. If soakaways i.e. plastic modules and soakaway rings are used, an infiltration test must be carried out to ensure that the capacity of the soil is suitable for infiltration. It must be demonstrated that there will be no increase in surface water flow being discharged offsite and an overall reduction in peak flow rate and volume.&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-a07fcd5a-7fff-f860-a355-91a099d96c60&quot;&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: In the interest of sustainable urban drainage.&lt;/span&gt;&lt;/p&gt;","&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Prior to the commencement of development, a qualified tree specialist must be appointed to provide arboricultural supervision and inspection. The details of this appointment and the specialist&#x27;s responsibilities must be submitted to and approved in writing by the Local Planning Authority. The submission should include the methodology and programme for reporting, as well as a timetable for inspections.&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;The approved works must be carried out in strict accordance with the approved details. Upon completion of the development, a report from the appointed arboriculturist must be submitted to and approved in writing by the Local Planning Authority, confirming that all tree protection measures and tree works were carried out in accordance with the approved plans accompanied by photographs taken at critical stages.&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-353f0531-7fff-6cc4-f016-5378931a6cab&quot;&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: to ensure that works affecting trees are carried out in a professional and controlled manner, safeguarding their health and long-term viability. This is in accordance with good arboricultural practice and is supported by BS 5837:2012 and Policy LP51 of the Hackney Local Plan 2033.&lt;/span&gt;&lt;/p&gt;","&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;All new underground utility apparatus, including drainage, shall be routed and installed outside the Root Protection Area(s) (RPAs) shown on the approved drawings. Should it not be feasible to route new underground utility apparatus outside the RPAs of retained trees, trenchless insertion methods (as detailed in BS 5837:2012, Table 3) shall be employed for their installation within the RPAs, with entry and retrieval pits sited outside the RPAs. No other new underground utilities shall be installed within the RPAs of retained trees without prior written consent from the Local Planning Authority (LPA). Any such works, if permitted, shall be carried out in strict accordance with the principles of BS 5837:2012 &quot;Trees in relation to design, demolition and construction – Recommendations&quot; and the National Joint Utilities Group Guidelines for the planning, installation and maintenance of utility apparatus in proximity to trees, Volume 4, Issue 2 (2007) (or any standard that reproduces or replaces this standard).&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-ba0bd77d-7fff-a5d3-af3a-17d258eab5b1&quot;&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;background-color:#ffffff;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(34, 34, 34); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: To safeguard existing tree(s) in the interests of visual amenity and long-term tree health, having regard to Policy LP51 in the Local Plan 2033 (adopted 2020). Prior approval is required to ensure that important trees are not permanently damaged or lost due to root disturbance or changes in soil hydrology.&lt;/span&gt;&lt;/p&gt;","&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;The development shall not be occupied until details of boundary walls, fences, screens or other means of enclosure have been submitted to and approved in writing by the Local Planning Authority. The development shall not be occupied unless the boundaries have been implemented in accordance with the approved details and shall be permanently retained as such thereafter.&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-2752eee4-7fff-0419-0068-b6b73630d637&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: To be compatible with the existing townscape including urban grain and plot division; and to improve the public realm, frontage to the street and facilitate movement through areas with direct, safe, accessible, and easily recognisable routes&lt;/span&gt;&lt;/p&gt;","&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Prior to the occupation of the development hereby approved, full details including as built ASHP system (or any other related fixed plant adopted) specification and supporting drawings and installation certificates by a MCS registered contractor must be submitted to and approved in writing by the Local Planning Authority&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;margin-left: 30pt;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;a) Minimum Heat pump Coefficient of Performance&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;margin-left: 30pt;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;b) Minimum Heat pump Seasonal Coefficient of Performance&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;margin-left: 30pt;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;c) Details of location of the condenser units from the heat pump systems and any noise solutions to mitigate the impact for nearby sensitive receptors&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-f8bfabfa-7fff-5655-3499-0555818f0c1c&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: In the interest of addressing climate change and securing sustainable and net zero development and construction, in accordance with LP55 of the Hackney Local Plan&lt;/span&gt;&lt;/p&gt;","&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Prior to the occupation of the development hereby approved, air permeability certificates demonstrating that a maximum of 3 m3/(m2.h) at 50 Pa has been achieved must prepared by a suitable contractor must be submitted to and approved in writing by the Local Planning Authority&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-5df98fac-7fff-913f-7922-d54a15b4f902&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: In the interest of addressing climate change and securing sustainable and net zero development and construction, in accordance with LP55 of the Hackney Local Plan&lt;/span&gt;&lt;/p&gt;","&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;Prior to the above ground works of the development hereby approved, an overheating risk assessment including a detailed statement demonstrating how each stage of the Cooling hierarchy has been followed and supported by the results of the Good Homes Alliance Early Stage Overheating Risk Tool shall be submitted and approved in writing by the Local Planning Authority&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-81cdcb92-7fff-e746-ba92-52217ac6c55b&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height:1.38;text-align: justify;margin-top:0pt;margin-bottom:0pt;&quot;&gt;&lt;span style=&quot;font-size: 14px; font-family: Arial, sans-serif; color: rgb(0, 0, 0); background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON: In the interest of addressing climate change and securing sustainable and net zero development and construction, in accordance with LP55 of the Hackney Local Plan&lt;/span&gt;&lt;/p&gt;"],"last_synced":"2026-06-28T01:51:46.914Z","centroid_northing":186473,"url_planning_app":"https://developmentandhousing.hackney.gov.uk//planning/index.html?fa=getApplication&id=83873","lpa_app_no":"2025/1761","site_number":"139","ward":"Brownswood Ward","locality":"London","last_date_consultation_comments":"01/12/2025","date_building_work_started_under_previous_permission":null,"description":"Construction of new 1-Bed / 2-Person dwelling on land to the rear of the site and upgrading the external amenity area for all residents.","parking_details":{"no_existing_cycle":4,"no_proposed_cycle":6,"net_cycle":2},"postcode":"N4 2JW","appeal_status":null,"cil_liability":null,"date_building_work_completed_under_previous_permission":null,"pp_id":"14224997","status":"Application Under Consideration","last_updated_by":"Planning Portal ingest","polygon":{"crs":{"type":"name","properties":{"name":"EPSG:27700"}},"type":"GeometryCollection","geometries":[{"coordinates":[[[531826.75,186468.45],[531830.4994049845,186464.282168251],[531837.65,186456.8],[531838.55,186456.4],[531839.1,186456.5],[531839.7,186456.9],[531841.46,186458.45],[531858.55,186473.45],[531845.65,186486.4],[531826.75,186468.45]]],"type":"Polygon"}]},"wgs84_polygon":{"coordinates":[[[-0.09963,51.561697],[-0.099578,51.561658],[-0.099477,51.561589],[-0.099465,51.561586],[-0.099457,51.561586],[-0.099448,51.56159],[-0.099422,51.561603],[-0.09917,51.561734],[-0.099351,51.561854],[-0.09963,51.561697]]],"type":"Polygon"},"appeal_decision_date":null,"secondary_street_name":null,"lapsed_date":null,"bo_system":"Portal","decision_date":null,"centroid_easting":531835,"actual_commencement_date":null,"id":"Hackney-2025_1761","lpa_name":"Hackney","decision_target_date":"30/12/2025","valid_date":"04/11/2025","development_type":"Minor dwellings","last_updated":"2026-06-27T21:21:26.875Z","subdivision_of_building":"Undeveloped Land to the rear","reference_no_of_permission_being_relied_on":null,"centroid":{"lat":51.561736,"lon":-0.09951},"decision_process":"Delegated","application_type_full":"Full planning permission","decision_agency":"Borough","street_name":"Blackstock Road","appeal_decision":null,"title_number":null,"site_name":"139 Abraco","appeal_start_date":null,"application_details":{"other_residential_accommodation_details":{"site_area":466},"site_area":0.0466,"affordable_housing_fast_track":false,"phasing_details":[{"phase_detail":"Whole development","intended_completion_date":"08/2026","intended_commencement_date":"02/2026"}],"total_gia_gained":50.2,"total_gia_existing":555,"total_gia_lost":0,"existing_proposed_floorspace_details":[{"gia_existing":480,"gia_gained":50.2,"use_class":"C3","gia_lost":0},{"gia_existing":75,"gia_gained":0,"use_class":"EB","gia_lost":0}],"projected_cost_of_works":"Up to £2m","occupation_status":"Occupied","rain_water_harvesting":true,"scheme_phasing":true,"building_details":[{"no_storeys":1,"max_height":4,"building_ref":"New Home"}],"grey_water_reuse":false,"surface_water_discharge_percentage_reduction":20,"green_suds":true,"non_residential_details":{"total_non_resi_gross_internal_floor_area_to_be_gained":0,"total_non_resi_gross_internal_floor_area_to_be_lost":0,"total_gia_gained":50.2,"total_gia_lost":0,"total_gia_existing":555},"garden_land_lost":false,"residential_details":{"total_no_proposed_residential_units_shared_equity":0,"total_no_proposed_bedrooms":1,"total_no_proposed_residential_units":1,"total_no_proposed_residential_units_london_living_rent":0,"total_no_proposed_residential_affordable_units":0,"total_no_existing_residential_units":0,"total_no_proposed_residential_units_affordable_rent":0,"total_no_proposed_residential_units_discount_market_sale":0,"total_no_proposed_residential_units_discount_market_rent_charged_at_london_rents":0,"total_no_existing_residential_units_london_living_rent":0,"total_no_existing_residential_units_shared_equity":0,"total_no_existing_residential_units_market_for_sale":0,"total_no_existing_residential_units_intermediate":0,"total_no_proposed_residential_units_market_for_rent":1,"total_no_existing_residential_units_social_rent":0,"total_no_proposed_residential_units_self_build_and_custom_build":0,"total_no_existing_residential_units_discount_market_rent":0,"total_no_proposed_residential_units_market_for_sale":0,"total_no_existing_residential_affordable_units":0,"total_no_existing_residential_units_affordable_rent":0,"habitable_rooms_density":null,"total_no_existing_residential_units_london_shared_ownership":0,"total_gia_gained":50.2,"total_no_proposed_residential_units_social_rent":0,"total_no_existing_residential_units_london_affordable_rent":0,"dwelling_density":0,"total_no_proposed_residential_units_london_affordable_rent":0,"total_no_existing_residential_units_discount_market_sale":0,"total_no_proposed_residential_units_starter_homes":0,"total_no_existing_residential_units_discount_market_rent_charged_at_london_rents":0,"total_no_existing_residential_units_starter_homes":0,"total_no_proposed_residential_units_discount_market_rent":0,"total_no_proposed_residential_units_intermediate":0,"affordable_percentage":0.0,"total_no_proposed_residential_units_london_shared_ownership":0,"residential_units":[{"m43_2b_compliant":false,"m43_2a_compliant":false,"m42_compliant":true,"change_type":"Gain","garden_land":false,"sheltered_accommodation":false,"unit_type":"House or Bungalow","no_habitable_rooms":2,"provider":"Private","no_bedrooms":1,"provision_for_older_persons":false,"tenure":"Market for rent","gia":50.2}],"total_no_existing_residential_units_market_for_rent":0,"total_no_existing_residential_units_self_build_and_custom_build":0},"internal_resi_water_usage":125,"infrastructure_details":{"total_annual_pm_emissions":0,"no_resi_units_to_have_full_fibre":1,"green_roof_area":0,"urban_greening_factor_score":0.12,"no_homes_passive_cooling":0,"no_new_water_connections_required":1,"no_non_resi_units_to_have_full_fibre":0,"total_annual_nox_emissions":0,"waste_provision":true,"percentage_demolition_construction_material_recycling":60,"no_homes_to_have_electrical_heating":1,"mobile_network_operators_consultation":false,"fire_suppression_system_proposed":false,"no_new_gas_connections_required":0,"ghg_reduction_over_building_regulations":true},"ownership_status":"Private","lead_developer_company_name":"Lambros and Fedra Investments Ltd"},"epc_number":null,"uprn":10092058440,"actual_completion_date":null}