{"borough":"Hackney","application_type":"All Other","decision":"Approved","decision_conditions":["<p>The Development hereby permitted shall only be carried out and completed strictly in accordance with the submitted plans hereby approved and any subsequent approval of details.\r\n</p><p><br></p><p>\r\nREASON: To ensure that the development hereby permitted is carried out in full accordance with the plans hereby approved.\r\n</p>","<p>The development hereby permitted must be begun not later than the expiration of three years beginning with the date of this permission.</p><p><br></p><p>\r\n</p><p>\r\nREASON: In order to comply with the provisions of the Town and Country Planning Act 1990 (as amended).</p><p>\r\n</p>","&lt;p dir=&quot;ltr&quot; style=&quot;line-height: 1.2; margin-top: 0pt; margin-bottom: 0pt;&quot;&gt;&lt;span style=&quot;font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; font-variant-emoji: normal; vertical-align: baseline;&quot;&gt;The noise level from all plant and machinery included in the approved development shall at all times remain 10dB(A) below background levels when measured at any nearby residential window.&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height: 1.2; margin-top: 0pt; margin-bottom: 0pt;&quot;&gt;&lt;span style=&quot;font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; font-variant-emoji: normal; vertical-align: baseline;&quot;&gt;REASON: To ensure that occupiers of neighbouring premises do not suffer a loss of amenity by reason of noise nuisance and other excess noise.&lt;/span&gt;&lt;/p&gt;","&lt;p&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;Following the removal of the tree as permitted by this decision, the tree shall be replaced by one of a suitable species, having regard for climate resilience and biodiversity value, in the front or rear garden.&lt;/span&gt;&lt;/p&gt;&lt;p style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;The replacement tree shall be planted during the planting season at the time of felling (end October - end March) or during the next immediately available planting season. The size of the tree shall be at least a Light Standard as per BS 3936-1:1992 (or any standard that reproduces or replaces this standard).&lt;/p&gt;&lt;p style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;For the discharge of this condition, written confirmation and clear photographic evidence showing the successfully planted replacement tree, its species, and its location, must be submitted to and approved in writing by the Local Planning Authority.&lt;/p&gt;&lt;p style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;The tree shall be maintained for 5 years after planting. Should it be removed, die, be severely damaged, or become seriously diseased within this 5-year period, it shall be replaced with another tree as originally required by this condition, and new written confirmation and photographic evidence of the remedial planting must be submitted to the Local Planning Authority within one month of that replacement planting.&lt;/p&gt;&lt;p style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;REASON: In the interests of visual amenity, having regard to Policy LP51 in the Local Plan 2033 (adopted 2020).&lt;/p&gt;","&lt;p dir=&quot;ltr&quot; style=&quot;line-height: 1.2; text-align: justify; margin-top: 0pt; margin-bottom: 0pt;&quot;&gt;&lt;span style=&quot;font-size:11pt;font-family:Arial,sans-serif;color:#000000;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;white-space:pre-wrap;&quot;&gt;Prior to superstructure works, detailed specification and a drainage layout of at least one suitable sustainable drainage systems (i.e. water butt with overflow, raingarden, bioretention planter box, living roof (substrate depth of 80-150mm excluding the vegetative mat), permeable paving, etc.) shall be submitted to, and approved by the LPA, in consultation with the LLFA. If soakaways i.e. plastic modules and soakaway rings are used, an infiltration test must be carried out to ensure that the capacity of the soil is suitable for infiltration. It must be demonstrated that there will be no increase in surface water flow being discharged offsite and an overall reduction in peak flow rate and volume&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span id=&quot;docs-internal-guid-1921304d-7fff-ec10-e321-827dcb659224&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot; style=&quot;line-height: 1.2; text-align: justify; margin-top: 0pt; margin-bottom: 0pt;&quot;&gt;&lt;span style=&quot;font-size:11pt;font-family:Arial,sans-serif;color:#000000;background-color:transparent;font-weight:400;font-style:normal;font-variant:normal;text-decoration:none;vertical-align:baseline;white-space:pre;white-space:pre-wrap;&quot;&gt;REASON: To ensure the provision of sustainable drainage measures onsite&lt;/span&gt;&lt;/p&gt;","&lt;p&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;The tree works hereby approved shall be carried out strictly in accordance with the description in 9.0 Tree Works Schedule of the Arboricultural Report by Marcus Foster, dated November 2025, and must be undertaken by a suitably qualified tree surgeon, in accordance with BS3998:2010 ‘Recommendations for tree works’ (or any standard that reproduces or replaces this standard).&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;REASON: &amp;nbsp;In the interests of visual amenity and good arboricultural practice, having regard to Policy LP51 in the Local Plan 2033 (adopted 2020).&lt;/span&gt;&lt;/p&gt;","&lt;p&gt;&lt;span id=&quot;docs-internal-guid-843a148f-7fff-c748-1bdc-e0204fb2792c&quot;&gt;&lt;span style=&quot;font-size: 10pt; font-family: Arial, sans-serif; color: rgb(34, 34, 34); font-weight: 700; font-variant: normal; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 10pt; font-family: Arial, sans-serif; color: rgb(34, 34, 34); font-variant: normal; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;A scheme for the provision and implementation of flood resilient and resistant construction details and measures for the site against surface water flood risk shall be submitted to and agreed, in writing with the LPA in consultation with the LLFA prior to the construction of the measures. The scheme shall be carried out in its entirety before the outbuilding is occupied and; constructed and completed in accordance with the approved plans in line with current best practices. &lt;/span&gt;&lt;span style=&quot;font-size: 10pt; font-family: Arial, sans-serif; color: rgb(34, 34, 34); font-weight: 700; font-variant: normal; vertical-align: baseline; white-space: pre-wrap;&quot;&gt;REASON:&lt;/span&gt;&lt;span style=&quot;font-size: 10pt; font-family: Arial, sans-serif; color: rgb(34, 34, 34); font-variant: normal; vertical-align: baseline; white-space: pre-wrap;&quot;&gt; To mitigate against the effects of surface water flooding.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;","&lt;p&gt;&lt;span style=&quot;font-family: Arial; font-size: small;&quot;&gt;&amp;nbsp;No development shall commence, other than works of demolition, until a report (including intrusive investigation/trial pit and monitoring where necessary) demonstrating that the&amp;nbsp; development will not increase the potential for groundwater flooding to itself or to the surrounding area during and post-construction has been submitted to the Local Planning Authority for approval. Where groundwater is identified as a potential risk, details of appropriate controls including flood resilience and/or resistance measures shall be submitted to the LPA for approval and the approved measures incorporated before the basement is occupied. The basement shall be constructed and completed in accordance with the approved plans in line with BS 8102:2022 Protection of below ground structures against water ingress - code of practice&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;span style=&quot;font-family: Arial; font-size: small;&quot;&gt;Reason:&amp;nbsp;&lt;/span&gt;To prevent increased groundwater flood risk and ensure appropriate flood mitigation measures&lt;/p&gt;","&lt;p&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;The works hereby approved shall not be carried out unless in accordance with the approved Tree Protection Plan and Arboricultural Method Statement. The measures set out in the Tree Protection Plan shall remain in place until the completion of the construction. Any permanent hard surfacing within RPAs of retained trees should be installed and maintained in line with the approved AMS using a ‘no-dig’ method as outlined within the report.&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;REASON: To safeguard existing tree(s) in the interests of visual amenity, having regard to Policy LP51 in the Local Plan 2033 (adopted 2020) and pursuant to Section 197 of the Town and Country Planning Act 1990.&lt;/span&gt;&lt;/p&gt;","&lt;p data-start=&quot;0&quot; data-end=&quot;363&quot;&gt;Detailed drawings and full particulars of the proposed development, including the matters set out below, shall be submitted to and approved in writing by the Local Planning Authority before the relevant part of the works are commenced. The development shall thereafter be carried out only in accordance with the approved details and retained as such thereafter.&lt;/p&gt;&lt;p data-start=&quot;365&quot; data-end=&quot;580&quot;&gt;a) Detailed drawings and specifications of all replacement windows, including sections at scales of 1:20&amp;nbsp; showing profiles, glazing bars, reveals, cills, headers, materials, finishes, and method of opening;&lt;/p&gt;&lt;p data-start=&quot;582&quot; data-end=&quot;785&quot;&gt;b) Detailed drawings and specifications of all new windows and doors, including sections at scales of 1.20 showing profiles, reveals, cills, headers, materials, finishes, and method of opening;&lt;/p&gt;&lt;p data-start=&quot;787&quot; data-end=&quot;934&quot;&gt;c) Detailed drawings and samples/details of the proposed brickwork, including the bagged brick finish, mortar mix, bonding pattern, and pointing;&lt;/p&gt;&lt;p data-start=&quot;365&quot; data-end=&quot;608&quot;&gt;\r\n\r\n\r\n&lt;/p&gt;&lt;p data-start=&quot;936&quot; data-end=&quot;1082&quot;&gt;d) Detailed drawings and specifications of the proposed render finish, including colour, texture, depth, and junctions with adjoining materials.&lt;/p&gt;&lt;p&gt;\r\n\r\n\r\n\r\n&lt;/p&gt;&lt;p data-start=&quot;907&quot; data-end=&quot;1184&quot; data-is-last-node=&quot;&quot; data-is-only-node=&quot;&quot;&gt;REASON: To ensure a high quality design and appearance that preserves the character and appearance of the host building and the wider conservation area,&lt;/p&gt;","&lt;div&gt;All new underground utility apparatus, including drainage, shall be routed and installed outside the Root Protection Area(s) (RPAs) shown on the approved drawings. Should it not be feasible to&amp;nbsp;&lt;span class=&quot;il&quot;&gt;route&lt;/span&gt;&amp;nbsp;new underground utility apparatus outside the RPAs of retained trees, trenchless insertion methods (as detailed in BS 5837:2012, Table 3) shall be employed for their installation within the RPAs, with entry and retrieval pits sited outside the RPAs. No other new underground utilities shall be installed within the RPAs of retained trees without prior written consent from the Local Planning Authority (LPA). Any such works, if permitted, shall be carried out in strict accordance with the principles of BS 5837:2012 &quot;Trees in relation to design, demolition and construction – Recommendations&quot; and the National Joint Utilities Group Guidelines for the planning, installation and maintenance of utility apparatus in proximity to trees, Volume 4, Issue 2 (2007) (or any standard that reproduces or replaces this standard).&lt;br&gt;&lt;br&gt;REASON: To safeguard existing tree(s) in the interests of visual amenity and long-term tree health, having regard to Policy LP51 in the Local Plan 2033 (adopted 2020). Prior approval is required to ensure that important trees are not permanently damaged or lost due to root disturbance or changes in soil hydrology.&lt;br&gt;&lt;/div&gt;&lt;div&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;/div&gt;","&lt;p&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;Prior to the commencement of development, a qualified tree specialist must be appointed to provide arboricultural supervision and inspection. The details of this appointment and the specialist&#x27;s responsibilities must be submitted to and approved in writing by the Local Planning Authority. The submission should include the methodology and program for reporting, as well as a timetable for inspections.&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;The approved works must be carried out in strict accordance with the approved details. Upon completion of the development, a report from the appointed arboriculturist must be submitted to and approved in writing by the Local Planning Authority, confirming that all tree protection measures and tree works were carried out in accordance with the approved plans accompanied by photographs taken at critical stages.&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Arial, Helvetica, sans-serif; font-size: small;&quot;&gt;REASON: to ensure that works affecting trees are carried out in a professional and controlled manner, safeguarding their health and long-term viability. This is in accordance with good arboricultural practice and is supported by BS 5837:2012 and Policy LP51 of the Hackney Local Plan 2033.&lt;/span&gt;&lt;/p&gt;","&lt;p&gt;The roof of the rear extension hereby approved shall not be used as a terrace, balcony or similar amenity area.\r\n&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;\r\nREASON: In the interests of neighbours amenity\r\n&lt;/p&gt;"],"last_synced":"2026-06-29T01:41:53.291Z","centroid_northing":184637,"url_planning_app":"https://developmentandhousing.hackney.gov.uk//planning/index.html?fa=getApplication&id=83897","lpa_app_no":"2025/2418","site_number":20,"ward":"Hackney Central Ward","locality":"London","last_date_consultation_comments":"07/03/2026","date_building_work_started_under_previous_permission":null,"description":"Conversion of five residential flats back into a single-family dwelling, adding a part single, part two-storey rear extension as well as a full refurbishment of the interior, external works to the front and rear including replacement windows and and the addition of a projecting porch.","parking_details":null,"postcode":"E8 1AD","appeal_status":null,"cil_liability":null,"date_building_work_completed_under_previous_permission":null,"pp_id":"14455156","status":"Approved","last_updated_by":"Planning Portal ingest","polygon":{"crs":{"type":"name","properties":{"name":"EPSG:27700"}},"type":"GeometryCollection","geometries":[{"coordinates":[[[534540.15,184635.2],[534549,184638.45],[534565.9,184644.8],[534565.75,184645.15],[534564.35,184649.8],[534563.7,184651.95],[534560.35,184650.7],[534519.1,184635.6],[534521.8,184628.35],[534530.1,184631.45],[534540.15,184635.2]]],"type":"Polygon"}]},"wgs84_polygon":{"coordinates":[[[-0.061211,51.544582],[-0.061082,51.54461],[-0.060836,51.544663],[-0.060838,51.544666],[-0.060856,51.544708],[-0.060865,51.544727],[-0.060914,51.544717],[-0.061514,51.544591],[-0.061478,51.544525],[-0.061357,51.544551],[-0.061211,51.544582]]],"type":"Polygon"},"appeal_decision_date":null,"secondary_street_name":null,"lapsed_date":"15/05/2029","bo_system":"Portal","decision_date":"15/05/2026","centroid_easting":534535,"actual_commencement_date":null,"id":"Hackney-2025_2418","lpa_name":"Hackney","decision_target_date":"29/12/2025","valid_date":"03/11/2025","development_type":"Minor all other minor developments","last_updated":"2026-06-28T11:34:22.564Z","subdivision_of_building":null,"reference_no_of_permission_being_relied_on":null,"centroid":{"lat":51.5446,"lon":-0.061284},"decision_process":"Delegated","application_type_full":"Full planning permission","decision_agency":"Borough","street_name":"Navarino Road","appeal_decision":null,"title_number":null,"site_name":null,"appeal_start_date":null,"application_details":{"other_residential_accommodation_details":{"site_area":349.1},"site_area":0.034910000000000004,"affordable_housing_fast_track":false,"phasing_details":[{"phase_detail":"Single phase","intended_completion_date":"09/2027","intended_commencement_date":"04/2026"}],"total_gia_gained":12.1,"total_gia_existing":269.2,"total_gia_lost":0,"existing_proposed_floorspace_details":[{"gia_existing":269.2,"gia_gained":12.1,"use_class":"C3","gia_lost":0}],"projected_cost_of_works":"Up to £2m","scheme_phasing":true,"rain_water_harvesting":false,"grey_water_reuse":false,"green_suds":true,"surface_water_discharge_percentage_reduction":50,"non_residential_details":{"total_non_resi_gross_internal_floor_area_to_be_gained":0,"total_non_resi_gross_internal_floor_area_to_be_lost":0,"total_gia_gained":12.1,"total_gia_existing":269.2,"total_gia_lost":0},"garden_land_lost":false,"internal_resi_water_usage":90,"infrastructure_details":{"total_annual_pm_emissions":0,"green_roof_area":0,"no_resi_units_to_have_full_fibre":1,"no_new_water_connections_required":0,"no_homes_passive_cooling":0,"no_non_resi_units_to_have_full_fibre":0,"total_annual_nox_emissions":0,"waste_provision":true,"percentage_demolition_construction_material_recycling":0,"no_homes_to_have_electrical_heating":0,"mobile_network_operators_consultation":false,"fire_suppression_system_proposed":true,"no_new_gas_connections_required":0,"ghg_reduction_over_building_regulations":false,"chp_heat_pumps_capacity":8.5,"urban_greening_factor_score":0},"ownership_status":"Private","occupation_status":"Occupied"},"epc_number":"9940-2801-7799-9795-3145","uprn":100023013961,"actual_completion_date":null}