{"actual_commencement_date":null,"date_building_work_completed_under_previous_permission":null,"lpa_name":"Hackney","subdivision_of_building":null,"appeal_decision":null,"lapsed_date":"03/06/2029","appeal_decision_date":null,"last_updated_by":"Planning Portal ingest","reference_no_of_permission_being_relied_on":null,"epc_number":null,"last_updated":"2026-06-28T12:38:19.168Z","url_planning_app":"https://developmentandhousing.hackney.gov.uk//planning/index.html?fa=getApplication&id=84744","street_name":"Stamford Road","parking_details":{"no_proposed_car":1,"no_existing_car":1,"net_car":0},"ward":"De Beauvoir Ward","bo_system":"Portal","site_name":null,"site_number":27,"application_details":{"no_additional_bedrooms":1,"intended_commencement_date":"05/2026","intended_completion_date":"02/2027","total_gia_gained":43,"no_additional_bathrooms":0},"uprn":100021075713,"locality":"London","date_building_work_started_under_previous_permission":null,"postcode":"N1 4JP","valid_date":"02/03/2026","cil_liability":null,"actual_completion_date":null,"centroid":{"lat":51.54384,"lon":-0.078507},"centroid_easting":533343,"application_type_full":"Householder planning & demolition in a conservation area","pp_id":"14712866","lpa_app_no":"2026/0364","polygon":{"geometries":[{"coordinates":[[[533333.864,184523.988],[533336.648,184520.997],[533342.134,184515.102],[533345.3,184511.7],[533351.55,184517.3],[533348.5,184520.65],[533343.098,184526.546],[533339.784,184530.185],[533339.148,184530.896],[533330.85,184540.1],[533322.95,184547.65],[533315.75,184553.15],[533311.1,184547.7],[533314.45,184544.3],[533324.5,184534.05],[533333.864,184523.988]]],"type":"Polygon"}],"crs":{"properties":{"name":"EPSG:27700"},"type":"name"},"type":"GeometryCollection"},"id":"Hackney-2026_0364","appeal_status":null,"appeal_start_date":null,"description":"Alterations to an existing single storey rear extension to include a new aluminium sliding door to replace an existing bi-folding aluminium door, replacement roof and roof light and replacement brick wall to the rear elevation; the addition of a new upper ground / first floor rear extension in brick, the replacement of existing sliding sash windows like-for-like with heritage double-glazing; the installation of roof mounted air conditioning unit; the construction of a garden room; the construction of a new covered waste & recycling store and minor landscaping improvements at the front and the rear.","development_type":"Other house holder developments","decision_conditions":["<p>The Development hereby permitted shall only be carried out and completed strictly in accordance with the submitted plans hereby approved and any subsequent approval of details.\r\n</p><p><br></p><p>\r\nREASON: To ensure that the development hereby permitted is carried out in full accordance with the plans hereby approved.\r\n</p>","<p>The development hereby permitted must be begun not later than the expiration of three years beginning with the date of this permission.</p><p><br></p><p>\r\n</p><p>\r\nREASON: In order to comply with the provisions of the Town and Country Planning Act 1990 (as amended).</p><p>\r\n</p>","&lt;p&gt;Foundation and Sub-Structure within Root Protection Area (RPA)&lt;/p&gt;&lt;p&gt;The outbuilding&#x27;s foundation and sub-structure within the Root Protection Area (RPA) of the retained trees shall be implemented in strict accordance with the following requirements:&lt;/p&gt;&lt;p&gt;1. Foundation Type: The foundation for the outbuilding shall be constructed with hand tools only, using screw piles. No mechanical excavation, traditional strip foundations, continuous beams, or trenching shall be used within the RPAs of retained trees as identified in the approved Arboricultural Report ref. AIA/MF/0102/26 dated May 2026.&lt;/p&gt;&lt;p&gt;2. Gaseous Exchange: The finished sub-structure shall be a suspended ground floor/slab creating a ventilated air space between the underside of the structure and the existing soil surface to ensure:&lt;/p&gt;&lt;p&gt;- Gaseous Exchange: Free exchange of air and gases (oxygen and carbon dioxide) between the soil and the atmosphere to maintain a healthy rooting environment.&lt;/p&gt;&lt;p&gt;- Soil Hydrology: The design should encourage the natural movement and infiltration of rainfall into the soil beneath the structure.&lt;/p&gt;&lt;p&gt;REASON: To safeguard the long-term health, stability, and viability of the retained trees by minimizing soil disturbance in accordance with the principles of BS 5837:2012 &quot;Trees in relation to design, demolition and construction – Recommendations&quot; in the interests of the visual amenity of the surrounding area.&amp;nbsp;&lt;/p&gt;","&lt;p&gt;The works hereby approved shall not be carried out unless in accordance with the approved Arboricultural Method Statement (AMS) and Tree Protection Plan (TPP) ref. AIA/MF/0102/26 dated May 2026.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;REASON: To safeguard existing trees in the interests of the visual amenities of the surrounding area.&lt;/p&gt;","&lt;p&gt;Prior to the occupation of the development hereby approved, details and full specifications of 1 bird box, 1 swift brick/box, and 1 bat box shall be submitted to and approved in writing by the local planning authority and shall be maintained for the lifespan of the development. The details should include:&lt;/p&gt;&lt;p&gt;A minimum of 1 swift brick (same requirements for swift box) incorporated into the design of the development. They should be installed in groups of at least 2, and placed at or close to eaves level of the development hereby approved. They should be placed at least 5m above the ground with a 5m unobstructed flight path, both below and in front of the swift brick. The swift brick should be located facing north, east, or north east (direct sunlight should be avoided) and should not be placed immediately above doors or windows. Where possible, swift bricks should be set flush into the external wall to match adjacent brickwork.&lt;/p&gt;&lt;p&gt;A minimum of 1 bird box incorporated into the design of the development, with a variety of box types (including different sized entrance holes) to provide habitat for diverse bird species. The boxes should be installed at or close to the eaves level of the development hereby approved. The boxes should be between 3 and 5 metres from the ground, and there should be a clear flight path without any obstructions below and directly in front of the box. The boxes should be facing north, east or north east (direct sunlight should be avoided), and should not be placed immediately above doors or windows. Boxes located in the same area should not be placed too close together.&amp;nbsp;&lt;/p&gt;&lt;p&gt;A minimum of 1 bat box incorporated into the design of the development. Boxes should be placed at or close to the eaves level of the development and at least 4m above the ground. The boxes should be placed away from artificial light sources and ideally located near dark tree lines or hedgerows where possible. The boxes should be located facing south, southeast or southwest, and exposed to sun for part of the day.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;REASON: To support bird and bat populations, including swifts, in Hackney and preserve endangered urban biodiversity, by providing nesting opportunities.&lt;/p&gt;","&lt;p style=&quot;&quot;&gt;The air source heat pump(s) hereby approved shall be installed and operated only in accordance with the specifications and noise levels assessed within the approved Noise Assessment prepared by Enviropass dated February 2026.&lt;/p&gt;&lt;p style=&quot;&quot;&gt;The cumulative rating level of noise emitted from the operation of the plant hereby approved shall be at least 5dB below the existing background noise level (LA90,T) when measured at the nearest noise-sensitive premises and shall achieve compliance with the MCS Planning Standards. The equipment shall thereafter be permanently retained as approved.&lt;/p&gt;&lt;p style=&quot;&quot;&gt;REASON: To safeguard the amenities of neighbouring occupiers.&lt;/p&gt;","&lt;p&gt;Prior to superstructure of the proposed outbuilding, detailed specification, a drainage layout and a management &amp;amp; maintenance plan (where applicable) of at least one suitable sustainable drainage system (i.e. water butt with overflow, raingarden, bioretention planter box, living roof (substrate depth of 80-150mm excluding the vegetative mat), permeable paving etc.) shall be submitted to, and approved by the LPA, in consultation with the LLFA. If soakaways i.e. plastic modules and soakaway rings are used, an infiltration test must be carried out to ensure that the capacity of the soil is suitable for infiltration. It must be demonstrated that there will be no increase in surface water flow being discharged offsite and an overall reduction in peak flow rate and volume.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;REASON: In the interest of sustainable urban drainage.&lt;/p&gt;","&lt;p&gt;All new underground utility apparatus, including drainage, shall be routed and installed outside the Root Protection Area(s) (RPAs) shown on the approved drawings. Should it not be feasible to route new underground utility apparatus outside the RPAs of retained trees, trenchless insertion methods (as detailed in BS 5837:2012, Table 3) shall be employed for their installation within the RPAs, with entry and retrieval pits sited outside the RPAs. No other new underground utilities shall be installed within the RPAs of retained trees without prior written consent from the local planning authority (LPA). Any such works, if permitted, shall be carried out in strict accordance with the principles of BS 5837:2012 &quot;Trees in relation to design, demolition and construction – Recommendations&quot; and the National Joint Utilities Group Guidelines for the planning, installation and maintenance of utility apparatus in proximity to trees, Volume 4, Issue 2 (2007) (or any standard that reproduces or replaces this standard).&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;REASON: To safeguard existing tree(s) in the interests of visual amenity and long-term tree health. Prior approval is required to ensure that important trees are not permanently damaged or lost due to root disturbance or changes in soil hydrology.&lt;/p&gt;","&lt;p&gt;The roof of the ground and first floor rear extensions hereby approved shall not be used as a terrace, balcony or similar amenity area.\r\n&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;\r\nREASON: In the interests of neighbouring amenities.&lt;/p&gt;","&lt;p&gt;Detailed drawings and full particulars of the development hereby approved, in respect of the matters set out below, shall be submitted to and approved in writing by the local planning authority before the relevant part of the development is commenced. The development shall thereafter be carried out only in accordance with the approved details:&lt;/p&gt;&lt;p&gt;a) samples and details of all external materials and finishes to be used, including facing brickwork/cladding, roofing materials, and glazing;&lt;/p&gt;&lt;p&gt;b) typical window replacement details, including sections at a scale of 1:20, demonstrating reveal depths, frame profiles, and ensuring the overall thickness of the glazing units does not exceed 14mm; and&amp;nbsp;&lt;/p&gt;&lt;p&gt;c) drawings at a scale of 1:20 of proposed boundary treatments, including the bin store and planters.&lt;/p&gt;&lt;p&gt;REASON: To ensure a high quality external appearance and to safeguard the character and appearance of the building and surrounding area.&lt;/p&gt;","&lt;p&gt;To ensure the protection of trees on site, the development shall be carried out in accordance with the following requirements:&lt;/p&gt;&lt;p&gt;a) Prior to the commencement of development, a qualified tree specialist must be appointed to provide arboricultural supervision and inspection. The details of this appointment and the specialist&#x27;s responsibilities must be submitted to and approved in writing by the local planning authority. The submission should include the methodology and programme for reporting, as well as a timetable for inspections. The approved works must be carried out in strict accordance with the approved details. &lt;/p&gt;&lt;p&gt;b) Upon completion of the development, a report from the appointed arboriculturist must be submitted to and approved in writing by the local planning authority, confirming that all tree protection measures and tree works were carried out in accordance with the approved plans accompanied by photographs taken at critical stages.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;REASON: to ensure that works affecting trees are carried out in a professional and controlled manner, safeguarding their health and long-term viability.&amp;nbsp;&lt;/p&gt;"],"last_synced":"2026-06-29T01:42:53.466Z","secondary_street_name":null,"title_number":["LN224647"],"last_date_consultation_comments":"15/05/2026","decision_process":"Delegated","centroid_northing":184521,"borough":"Hackney","decision":"Approved","application_type":"Householder","wgs84_polygon":{"coordinates":[[[-0.078638,51.543869],[-0.078599,51.543842],[-0.078522,51.543787],[-0.078478,51.543756],[-0.078385,51.543805],[-0.078428,51.543836],[-0.078504,51.54389],[-0.07855,51.543923],[-0.078559,51.54393],[-0.078675,51.544015],[-0.078786,51.544084],[-0.078888,51.544135],[-0.078957,51.544088],[-0.07891,51.544056],[-0.078769,51.543962],[-0.078638,51.543869]]],"type":"Polygon"},"decision_agency":"Borough","decision_target_date":"27/04/2026","status":"Approved","decision_date":"03/06/2026"}