{"date_building_work_completed_under_previous_permission":null,"cil_liability":false,"wgs84_polygon":{"type":"Polygon","coordinates":[[[-0.187679,51.479038],[-0.18768,51.479011],[-0.187723,51.479011],[-0.187722,51.479038],[-0.187679,51.479038]]]},"postcode":"SW6 2EB","ward":"Parsons Green And Sandford","appeal_start_date":null,"appeal_decision":null,"valid_date":"24/03/2026","secondary_street_name":null,"centroid_northing":177120.0,"reference_no_of_permission_being_relied_on":null,"actual_commencement_date":null,"last_updated":"2026-10-19T14:00:00.714Z","description":"Change of use of the existing ancillary retail floorspace at first and second floor level (Use Class E(a)) into 1 x 1 bedroom self-contained residential flat (Use Class C3).","subdivision_of_building":"The proposal comprises a change of use at first- and second-floor levels only. ","epc_number":null,"url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/00833/FUL","borough":"Hammersmith & Fulham","street_name":"King's Road","decision_process":"Delegated","last_synced":"2026-10-21T16:11:34.071Z","last_updated_by":"Northgate M3","date_building_work_started_under_previous_permission":null,"application_type":"All Other","lapsed_date":"13/10/2029","last_date_consultation_comments":"20/05/2026","title_number":null,"appeal_status":null,"application_type_full":"Full planning permission","development_type":"Other change of use","decision_target_date":"19/05/2026","lpa_name":"Hammersmith & Fulham","uprn":"34074037","decision_date":"14/10/2026","lpa_app_no":"P/2026/00833/FUL","centroid_easting":525950.0,"appeal_decision_date":null,"decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of this planning permission.\r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).\r\n","Condition : 2 - The development hereby permitted shall be carried out in complete accordance with the following approved drawing numbers, other than where those details are altered pursuant to the conditions of this planning permission:\r\n\r\n-\tKR-DMA-00-DR-A-1100;\r\n-\tKR-DMA-01-DR-A-1101;\r\n-\tKR-DMA-02-DR-A-1102;\r\n-\tKR-DMA-ZZ-DR-A-2000;\r\n-\tKR-DMA-ZZ-DR-A-2001;\r\n-\tKR-DMA-ZZ-DR-A-2002;\r\n-\tKR-DMA-ZZ-DR-A-3100;\r\n-\tRecycling Management Plan received 24 March 2026.\r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.\r\n","Condition : 3 - The roof of the existing back addition shall not be converted into or used as a terrace or other open amenity space. No alterations shall be carried out; nor planters or other chattels placed on the roof/remainder of the roof of the back addition or the extension hereby approved. No railings or other means of enclosure shall be erected around the roof and no alterations shall be carried out to the property, including the extension hereby approved, to form an access onto the roof.  \r\n\r\nSuch a use would be detrimental to the amenities of neighbouring properties by reason of overlooking and loss of privacy and potential noise and disturbance, contrary to Policies CC11 and HO11 of the Local Plan (2018). \r\n","Condition : 4 - Prior to the occupation of the residential unit hereby permitted, refuse and recycling storage bins shall be installed as shown in the approved Refuse and Recycling Management Plan received 24 March 2026. Once provided the refuse storage and recycling facilities shall be permanently retained for this purpose.\r\n\t\t\t\t\r\nTo ensure that the use does not give rise to smell nuisance and to prevent harm to the street scene arising from the appearance of accumulated rubbish, in accordance with Policy CC7 of the Local Plan (2018).\r\n","Condition : 5 - Prior to commencement of above ground works in the development hereby permitted, a Ventilation Strategy Report to mitigate the impact of existing poor air quality for the self-contained dwellinghouse (Use Class C3) shall be submitted to and approved in writing by the Local Planning Authority. This is applicable to all residential floors where World Health Organisation Air Quality Guideline Values for Nitrogen Dioxide (NO2), and Particulate Matter (PM2.5, PM10) are exceeded and where current and future predicted pollutant concentrations are within 5% of these limits. The report shall include the following information: \r\n\r\na) Details and locations of the ventilation intakes at rear roof level or on the rear elevations of all residential floors\r\nb) Details and locations of ventilation extract to demonstrate that they are located a minimum of 2 metres away from the air ventilation intakes on all residential floors, to minimise the potential for the recirculation of extract air through the supply air ventilation intakes.\r\nc) Details of the independently tested mechanical ventilation system with Nitrogen Dioxide (NO2) and Particulate Matter (PM2.5, PM10) filtration with air intakes on the rear elevation to remove airborne pollutants. The filtration system shall have a minimum efficiency of 90% in the removal of Nitrogen Oxides/Dioxides, Particulate Matter (PM2.5, PM10) in accordance with BS EN ISO 10121-1:2014 and BS EN ISO 16890:2016.\r\n \r\nThe whole system shall be designed to prevent summer overheating and minimise energy usage. The maintenance and cleaning of the systems shall be undertaken regularly in accordance with manufacturer specifications and shall be the responsibility of the primary owner of the property. Approved details shall be fully implemented prior to the occupation/use of the development and thereafter permanently retained and maintained.\r\n\t\t\r\nTo ensure that the amenity of occupiers of the development site is not adversely affected by poor air quality, ","Condition : 6 - Prior to occupation of the development hereby permitted, details of a post installation compliance report including photographic confirmation of the mitigation measures as detailed in the approved ventilation strategy as required by condition 5 to mitigate the impact of existing poor air quality shall be submitted to and approved in writing by the Local Planning Authority. The report shall be produced by an accredited Chartered Building Surveyor (MRICS). Approved details shall be fully implemented prior to the occupation/use of the development and thereafter permanently retained and maintained.\r\n\t\t\r\nTo ensure that the amenity of occupiers of the development site is not adversely affected by poor air quality, in accordance with Policies CC10 and CC13 of the Hammersmith and Fulham Local Plan (2018).   \r\n","Condition : 7 - Prior to occupation of the development hereby permitted, details of the installation/commissioning reports of the Zero Emission MCS certified Air Source Heat Pump or Electric boiler to be provided for space heating and hot water for the self-contained dwellinghouse (Use Class C3) shall be submitted to and approved in writing by the Local Planning Authority. Approved details shall be fully implemented prior to the occupation/use of the development and thereafter permanently retained and maintained.\r\n\t\t\t\r\nTo ensure that the amenity of occupiers of the development site is not adversely affected by poor air quality, in accordance with Policies CC10 and CC13 of the Hammersmith and Fulham Local Plan (2018).   \r\n","Condition : 8 - The noise level in rooms at the development hereby approved shall meet the noise standard specified in BS8233:2014 for internal rooms and external amenity areas. \r\n\t\t\t\r\nTo ensure that the amenity of occupiers of the development site are not adversely affected by vibration, in accordance with Policies CC11 and CC1 of the Local Plan 2018.\r\n\r\n"],"site_number":"559","bo_system":"Northgate M3","status":"Approved","site_name":null,"decision":"Approved","polygon":{"type":"geometrycollection","geometries":[]},"centroid":{"lon":-0.187701,"lat":51.479025},"actual_completion_date":null,"pp_id":"14683128","decision_agency":"Borough","parking_details":null,"locality":"London","id":"Hammersmith_&_Fulham-P_2026_00833_FUL","application_details":{"affordable_housing_fast_track":true,"phasing_details":[{"phase_detail":"Entire Development","intended_commencement_date":"01/2027","intended_completion_date":"03/2027"}],"total_gia_gained":0,"site_area":0.01366,"total_gia_lost":70,"total_gia_existing":233,"existing_proposed_floorspace_details":[{"gia_existing":233,"use_class":"EA","gia_gained":0,"gia_lost":70}],"projected_cost_of_works":"Up to £2m","occupation_status":"Occupied","scheme_phasing":true,"rain_water_harvesting":false,"grey_water_reuse":false,"green_suds":false,"surface_water_discharge_percentage_reduction":0,"non_residential_details":{"total_non_resi_gross_internal_floor_area_to_be_gained":0,"total_non_resi_gross_internal_floor_area_to_be_lost":0,"total_gia_gained":0,"total_gia_lost":70,"total_gia_existing":233},"garden_land_lost":false,"residential_details":{"total_no_proposed_residential_units_shared_equity":0,"total_no_proposed_bedrooms":1,"total_no_proposed_residential_units":1,"total_no_proposed_residential_units_london_living_rent":0,"total_no_proposed_residential_affordable_units":0,"total_no_existing_residential_units":0,"total_no_proposed_residential_units_affordable_rent":0,"total_no_proposed_residential_units_discount_market_sale":0,"total_no_proposed_residential_units_discount_market_rent_charged_at_london_rents":0,"total_no_existing_residential_units_london_living_rent":0,"total_no_existing_residential_units_shared_equity":0,"total_no_existing_residential_units_market_for_sale":0,"total_no_existing_residential_units_intermediate":0,"total_no_proposed_residential_units_market_for_rent":1,"total_no_existing_residential_units_social_rent":0,"total_no_proposed_residential_units_self_build_and_custom_build":0,"total_no_existing_residential_units_discount_market_rent":0,"total_no_proposed_residential_units_market_for_sale":0,"total_no_existing_residential_affordable_units":0,"total_no_existing_residential_units_affordable_rent":0,"habitable_rooms_density":null,"total_no_existing_residential_units_london_shared_ownership":0,"total_gia_gained":66,"total_no_proposed_residential_units_social_rent":0,"total_no_existing_residential_units_london_affordable_rent":0,"dwelling_density":0,"total_no_proposed_residential_units_london_affordable_rent":0,"total_no_existing_residential_units_discount_market_sale":0,"total_no_proposed_residential_units_starter_homes":0,"total_no_existing_residential_units_discount_market_rent_charged_at_london_rents":0,"total_no_existing_residential_units_starter_homes":0,"total_no_proposed_residential_units_discount_market_rent":0,"total_no_proposed_residential_units_intermediate":0,"affordable_percentage":0.0,"total_no_proposed_residential_units_london_shared_ownership":0,"residential_units":[{"m43_2b_compliant":false,"m43_2a_compliant":false,"m42_compliant":false,"change_type":"Gain","sheltered_accommodation":false,"garden_land":false,"unit_type":"Flat Apartment Maisonette","provider":"Private","no_habitable_rooms":2,"no_bedrooms":1,"provision_for_older_persons":false,"gia":66,"tenure":"Market for rent"}],"total_no_existing_residential_units_market_for_rent":0,"total_no_existing_residential_units_self_build_and_custom_build":0},"infrastructure_details":{"total_annual_pm_emissions":0,"no_resi_units_to_have_full_fibre":1,"green_roof_area":0,"urban_greening_factor_score":0,"no_homes_passive_cooling":1,"no_new_water_connections_required":0,"no_non_resi_units_to_have_full_fibre":1,"total_annual_nox_emissions":0,"waste_provision":false,"percentage_demolition_construction_material_recycling":80,"no_homes_to_have_electrical_heating":1,"mobile_network_operators_consultation":false,"fire_suppression_system_proposed":false,"no_new_gas_connections_required":0,"waste_details":[{"external_dry_recycling":false,"external_food_waste":false,"unit_reference":"1","external_residual_waste":false,"reason_for_no_provision":"As the proposed development comprises a single residential unit, no external bin store is proposed. As set out in the Refuse and Recycling Management Plan submitted with the application, the unit will rely on LBHF’s kerbside sack collection service for general refuse and mixed recycling.","internal_residual_waste":true,"internal_food_waste":true,"internal_dry_recycling":true}],"ghg_reduction_over_building_regulations":false},"internal_resi_water_usage":105,"ownership_status":"Private"}}