{"date_building_work_completed_under_previous_permission":null,"cil_liability":false,"wgs84_polygon":{"type":"Polygon","coordinates":[[[-0.205335,51.468787],[-0.204851,51.46875],[-0.204867,51.468672],[-0.205351,51.468718],[-0.205335,51.468787]]]},"postcode":"SW6 3PS","ward":"Palace And Hurlingham","appeal_start_date":null,"appeal_decision":null,"valid_date":"23/04/2026","secondary_street_name":null,"centroid_northing":175947.0,"reference_no_of_permission_being_relied_on":null,"actual_commencement_date":null,"last_updated":"2026-07-15T07:40:00.572Z","description":"First-floor extension over existing ground floor rear extension, ground floor side glazed extension and replacement sliding doors at rear ground floor.","subdivision_of_building":null,"epc_number":null,"url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/00844/HH","borough":"Hammersmith & Fulham","street_name":"Napier Avenue","decision_process":"Delegated","last_synced":"2026-07-16T02:54:28.797Z","last_updated_by":"Northgate M3","date_building_work_started_under_previous_permission":null,"application_type":"Householder","lapsed_date":"14/07/2029","last_date_consultation_comments":"17/06/2026","title_number":["LN161271"],"appeal_status":null,"application_type_full":"Householder planning permission","development_type":"Other house holder developments","decision_target_date":"14/07/2026","lpa_name":"Hammersmith & Fulham","uprn":"34040407","decision_date":"14/07/2026","lpa_app_no":"P/2026/00844/HH","centroid_easting":524766.0,"appeal_decision_date":null,"decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of this planning permission.\r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).","Condition : 2 - The development hereby permitted shall be carried out in complete accordance with the following approved drawing numbers, other than where those details are altered pursuant to the conditions of this planning permission:\r\nSJC-25015-201-PP-GF-1F P2;\r\nSJC-25015-202-PP-RF P1;\r\nSJC-25015-210-PE-FR-RE P2;\r\nSJC-25015-211-PE-SI P2;\r\nSJC-25015-212-PE-SI P1;\r\nSJC-25015-221-PS-BB P2;\r\nFlood Risk Assessment. \r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.\r\n","Condition : 3 - The development hereby approved shall be carried out and completed in accordance with the materials details (including colour and finish) specified below;\r\n\r\n-Extension Walls: Yellow London stock brick/Gault brick to match the existing building in terms of brick and mortar colour and bond pattern.\r\n\r\n- Window: Timber sash double glazed.\r\n\r\n- Door: Timber double glazed.\r\n\r\nThe development shall be permanently retained in accordance with the approved details. Any works of making good to existing elevations shall be carried out in materials to match the elevation to which the works relate. \r\n\r\nTo ensure a satisfactory external appearance, in accordance with Policies DC1, DC4 and DC8 of the Local Plan (2018).\r\n","Condition : 4 - No part of any roof of the first and ground floor  extensions hereby approved shall be used as a roof terrace or other form of open amenity space. No alterations shall be carried out; nor planters or other chattels placed on the roofs. No railings or other means of enclosure shall be erected on the roofs, and no alterations shall be carried out to the property to form access onto the roofs. \r\n\r\nThe use of the roofs as terrace would increase the likelihood of harm to the existing residential amenities of the occupiers of neighbouring properties as a result of overlooking, noise and disturbance, contrary to Policies HO11 and CC11 of the Local Plan (2018). \r\n","Condition : 5 - No water tanks, water tank enclosures or other structures (excluding solar panels and air source heat pumps) shall be erected upon the roofs of the extensions hereby permitted.\r\n\r\nIt is considered that such structures would seriously detract from the appearance of the building, contrary to Policies DC4 and DC8 of the Local Plan (2018).\r\n","Condition : 6 - The development shall be carried out and completed in full accordance with the details contained within the approved Flood Risk Assessment Ref: 20250413 (by Green Structural Engineering, dated June 2026). No part of the development shall be used or occupied until all flood prevention and mitigation measures have been installed in accordance with the submitted details and the development shall be permanently retained in this form and maintained as necessary thereafter. \r\n\r\nTo limit the impact on flood risk and mitigate the susceptibility of the development to flooding in accordance with Policies CC2, CC3 and CC4 of the Local Plan (2018).\r\n"],"site_number":"27","bo_system":"Northgate M3","status":"Approved","site_name":null,"decision":"Approved","polygon":{"type":"geometrycollection","geometries":[{"coordinates":[[[524753.4177751546,175951.37625966838],[524787.1673386574,175948.07608783513],[524786.2173486234,175939.4261958243],[524752.4675756966,175943.72555963346],[524753.4177751546,175951.37625966838]]],"type":"Polygon"}]},"centroid":{"lon":-0.205156,"lat":51.468745},"actual_completion_date":null,"pp_id":"14693025","decision_agency":"Borough","parking_details":null,"locality":"London","id":"Hammersmith_&_Fulham-P_2026_00844_HH","application_details":{"total_gia_gained":9.94,"no_additional_bathrooms":0,"no_additional_bedrooms":0,"intended_completion_date":"12/2027","intended_commencement_date":"10/2026"}}