{"decision_target_date":"25/06/2026","url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/01104/HH","centroid":{"lat":51.471068,"lon":-0.204762},"decision_date":"25/06/2026","last_synced":"2026-07-03T02:42:18.106Z","wgs84_polygon":{"coordinates":[[[-0.204983,51.47105],[-0.204684,51.471113],[-0.204661,51.471072],[-0.204962,51.471007],[-0.204983,51.47105]]],"type":"Polygon"},"epc_number":null,"last_date_consultation_comments":"24/06/2026","decision_process":"Delegated","site_number":"20","last_updated":"2026-07-03T01:25:01.708Z","decision":"Approved","actual_commencement_date":null,"appeal_decision_date":null,"status":"Approved","bo_system":"Northgate M3","cil_liability":false,"development_type":"Other house holder developments","parking_details":null,"application_details":{"total_gia_gained":9,"no_additional_bedrooms":1,"intended_completion_date":"06/2027","no_additional_bathrooms":1,"intended_commencement_date":"06/2026"},"pp_id":"14883361","last_updated_by":"Planning Portal ingest","reference_no_of_permission_being_relied_on":null,"appeal_start_date":null,"lapsed_date":"25/06/2029","postcode":"SW6 3QE","uprn":"34042184","application_type":"Householder","subdivision_of_building":null,"ward":"Palace And Hurlingham","borough":"Hammersmith & Fulham","id":"Hammersmith_&_Fulham-P_2026_01104_HH","appeal_decision":null,"street_name":"Cristowe Road","secondary_street_name":null,"lpa_name":"Hammersmith & Fulham","date_building_work_completed_under_previous_permission":null,"title_number":["20CristoweRd"],"description":"Erection of a rear extension at second floor level, over part of the existing back addition;  installation of a rooflight to the flat roof over staircase at second floor level; installation of French doors and a Juliet balcony to the rear elevation of the existing rear roof extension; installation of an air-conditioning condenser unit to the flat roof of the proposed rear extension at second floor level; and installation of 5no. Photovoltaic solar panels to the flat roof of the existing mansard roof extension.","decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of this planning permission.\r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).","Condition : 2 - The development hereby permitted shall be carried out in complete accordance with the following approved drawing numbers, other than where those details are altered pursuant to the conditions of this planning permission:\r\n\r\n1702/301-1; \r\n1702/302-1; \r\n1702/303-1;\r\n1702/304-1;\r\n1702/305-1; and\r\n1702/306-1\r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.","Condition : 3 - The development hereby approved shall be carried out and completed in accordance with the materials details (including colour and finish) specified below:\r\n\r\n- Roof extension: Natural or artificial grey slates tiles which shall match the colour, shape and size of the existing roof\r\n\r\n- Windows: aluminium, colour, style, detail and finish to match the existing/original windows to be replaced.\r\n\r\nThe development shall be permanently retained in accordance with the approved details. Any works of making good to existing elevations shall be carried out in materials to match the elevation to which the works relate. \r\n\r\nTo ensure a satisfactory external appearance, in accordance with Policies DC1 and DC4 of the Local Plan (2018).\r\n\r\n\r\n","Condition : 4 - The balustrade of the Juliet balcony at second floor level in the west elevation 1702/306-1 hereby permitted shall be fixed flush with the rear elevation of the building at the same time as the associated doors are installed. The doors to the Juliet balconies shall open inwards only. The doors and balustrades shall be permanently retained in this form for the lifetime of the development.\r\n\r\nTo ensure a satisfactory external appearance and to protect the amenities of adjoining occupiers in terms of privacy and overlooking, in accordance with Policies DC1, DC4, DC8 and HO11 of the Local Plan (2018).\r\n\r\n","Condition : 5 - The roof the pod extension and the remaining roof of the existing back addition shall not be converted into or used as a terrace or other open amenity space. No alterations shall be carried out; nor planters or other chattels placed on the roofs of  the extension hereby approved. No railings or other means of enclosure shall be erected around the roofs and no alterations shall be carried out to the property, including the extension hereby approved, to form an access onto the roofs.\r\n\r\nSuch a use would be detrimental to the amenities of neighbouring properties by reason of overlooking and loss of privacy and potential noise and disturbance, contrary to Policies CC11 and HO11 of the Local Plan (2018).\r\n\r\n\r\n","Condition : 6 - Prior to the occupation of the development hereby permitted, the window at second floor level in the south elevation (1702/305-1) shall be fitted with obscure glass to a minimum level of obscurity equivalent to Pilkington Texture Glass Level 3, and shall be non-opening and fixed shut up to a height of 1.7m above the finished floor level. The window shall thereafter be permanently retained as approved.\r\n\r\nTo protect the amenities of adjoining occupiers in terms of privacy and overlooking in accordance with Policy HO11 of the Local Plan (2018).\r\n\r\n\r\n","Condition : 7 - The external sound level emitted from the air conditioning condenser unit at the development hereby approved shall be lower than the lowest existing background sound level by at least 10dBA in order to prevent any adverse impact. The assessment shall be made in accordance with BS4142:2014 at the nearest and/or most affected noise sensitive premises, with all machinery operating together at maximum capacity.\r\n\r\nTo ensure that the amenity of occupiers of the development site/ surrounding premises is not adversely affected by noise from mechanical installations/ equipment, in accordance with Policies CC11 and CC13 of the Local Plan 2018.\r\n","Condition : 8 - Prior to use, the air conditioning condenser unit at the development shall\r\nbe mounted with proprietary anti-vibration isolators and fan motors shall be vibration\r\nisolated from the casing and adequately silenced and maintained as such.\r\n\r\nReason: To ensure that the amenity of occupiers of the development site and\r\nsurrounding premises is not adversely affected by vibration, in accordance with Policies\r\nCC11 and CC13 of the Local Plan 2018."],"application_type_full":"Householder planning permission","actual_completion_date":null,"locality":"London","centroid_easting":524787.0,"lpa_app_no":"P/2026/01104/HH","valid_date":"30/04/2026","polygon":{"geometries":[{"coordinates":[[[524771.667655724,176203.6264056592],[524792.3174523807,176211.17676483106],[524794.0180696626,176206.5763293089],[524773.2678418985,176198.92670041753],[524771.667655724,176203.6264056592]]],"type":"Polygon"}],"type":"geometrycollection"},"decision_agency":"Borough","centroid_northing":176206.0,"site_name":null,"appeal_status":null,"date_building_work_started_under_previous_permission":null}