{"uprn":"34040967","ward":"Palace And Hurlingham","epc_number":null,"description":"Variation of Conditions 2 (approved Plans), 5 (obscure glazing) and 6 (Juliet balcony balustrades) of the planning permission reference: 2024/01749/FUL dated 20th December 2024 for the \"Erection of a rear roof extension, and erection of a rear extension at second floor level on top of the existing back addition, following the demolition of existing rear structure at roof level; erection of a single storey rear extension to the side and rear of the existing back addition, following the demolition of existing single storey rear conservatory; installation of a rooflight in the front roofslope; infilling an existing window to the side elevation, and installation of new French doors with a Juliette balcony to replace existing window to the rear elevation of existing first floor back addition; infilling an existing window, and installation of a new door with external steps to the side elevation, and installation of an air conditioning condenser unit within the side passage at ground floor level; landscaping of the rear garden; excavation of the front and part of the rear garden to form lightwells, including erection of a staircase from rear lightwell to rear garden, in connection with the enlargement of the existing basement.\" Amendments sought to include installation of solar PV panels to the flat roof at roof level, repositioning of rooflights to the front roofslope, amended elevation of the proposed ground floor rear extension, enlargement of the proposed basement into the rear garden and side passage with the formation of an additional rear lightwell. ","centroid_easting":524687.0,"decision_date":"30/07/2026","street_name":"Ranelagh Avenue","locality":"London","status":"Approved","date_building_work_started_under_previous_permission":null,"application_type_full":"Removal/Variation of a condition","lpa_name":"Hammersmith & Fulham","decision_target_date":"31/07/2026","lpa_app_no":"P/2026/01409/VAR","title_number":null,"decision":"Approved","last_updated":"2026-07-30T14:30:02.346Z","appeal_start_date":null,"actual_commencement_date":null,"bo_system":"Northgate M3","secondary_street_name":null,"decision_agency":"Borough","last_date_consultation_comments":"01/07/2026","appeal_decision_date":null,"actual_completion_date":null,"centroid_northing":175918.0,"wgs84_polygon":{"type":"Polygon","coordinates":[[[-0.206507,51.468547],[-0.206038,51.468513],[-0.206053,51.468445],[-0.206519,51.46848],[-0.206507,51.468547]]]},"date_building_work_completed_under_previous_permission":null,"lapsed_date":"30/07/2029","decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of the original decision dated 20th December 2024 (2024/01749/FUL).    \r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).","Condition : 2 - The development hereby permitted shall be carried out in complete accordance with the following approved drawing numbers, other than where those details are altered pursuant to the conditions of this planning permission:\r\n\r\nP/01; \r\nP/02; \r\nP/03; \r\nP/04; \r\nP/05; \r\nP/06 Rev.A; \r\nP/07 Rev.A; \r\nP/08; \r\nP/09; \r\nP/10; \r\nP/11 Rev.A; \r\nP/12; \r\nFlood Risk Assessment. \r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.","Condition : 3 - The development hereby approved shall be carried out and completed in accordance with the materials details (including colour and finish) specified below:\r\n\r\n- Walls: London stock brick to match the existing building in terms of brick and mortar colour and bond pattern.\r\n- Roof- flat: GRP Pitched\r\n- Windows: Timber sash frames, colour, style and finish to match the existing/original windows of the host property and windows to be replaced.\r\n- Ground floor rear Windows: Aluminium\r\n- Doors- ground floor and basement: Aluminium \r\n\r\nTo ensure a satisfactory external appearance, in accordance with Policies DC1, DC4 and DC8 of the Local Plan (2018).","Condition : 4 - No part of the basement hereby approved shall be occupied or used until the front lightwell has been constructed in accordance with the approved plans and the approved metal grille to the front lightwell has been fitted flush with the surrounding ground level. The metal grille shall be permanently retained in place thereafter. At no time shall railings or any other vertical element be constructed around the lightwell. \r\n\r\nTo ensure a suitable residential environment for future occupiers and a satisfactory external appearance and to prevent harm to the street scene, in accordance with Policies DC1, DC4, DC8 and DC11 of the Local Plan (2018) and Key Principles BL1, BL2 and BL3 of the Planning Guidance Supplementary Planning Document (2018). \r\n","Condition : 5 - Prior to the occupation of the development hereby permitted, the windows at first and second floor levels in the side of the rear addition elevation [P/11 Rev.A] shall be fitted with obscure glass to a minimum level of obscurity equivalent to Pilkington Texture Glass Level 3, and shall be non-opening and fixed shut up to a height of 1.7m above the finished floor level. The windows shall thereafter be permanently retained as approved. \r\n\r\nTo protect the amenities of adjoining occupiers in terms of privacy and overlooking in accordance with Policy HO11 of the Local Plan (2018). \r\n","Condition : 6 - The balustrades of the Juliet balconies at first and second floor level in the rear elevation [P/10] hereby permitted shall be fixed flush with the rear elevation of the building at the same time as the associated doors are installed. The doors to the Juliet balconies shall open inwards only. The doors and balustrades shall be permanently retained in this form for the lifetime of the development. \r\n\r\nTo ensure a satisfactory external appearance and to protect the amenities of adjoining occupiers in terms of privacy and overlooking, in accordance with Policies DC1, DC4, DC8 and HO11 of the Local Plan (2018). \r\n","Condition : 7 - No part of any roof of the single storey rear and side extensions or above the flat roof at second floor level hereby approved shall be used as a roof terrace or other form of open amenity space. No alterations shall be carried out; nor planters or other chattels placed on the roofs. No railings or other means of enclosure shall be erected on the roofs, and no alterations shall be carried out to the property to form access onto the roofs. \r\n\r\nThe use of the roof as a terrace would increase the likelihood of harm to the existing residential amenities of the occupiers of neighbouring properties as a result of overlooking, noise and disturbance, contrary to Policies HO11 and CC11 of the Local Plan (2018). \r\n","Condition : 8 - The development shall be carried out and completed in full accordance with the details contained within the approved Flood Risk Assessment [by Planning Solutions Ltd]. No part of the development shall be used or occupied until all flood prevention and mitigation measures have been installed in accordance with the submitted details and the development shall be permanently retained in this form and maintained as necessary thereafter. \r\n\r\nTo limit the impact on flood risk and mitigate the susceptibility of the development to flooding in accordance with Policies CC2, CC3 and CC4 of the Local Plan (2018). \r\n","Condition : 9 - The measures of the proposed air conditioning unit shall be lower than the lowest existing background sound level by at least 10dBA in order to prevent any adverse impact. The proposed unit shall run in accordance with BS4142:2014 at the nearest and/or most affected noise sensitive premises. Approved details shall be implemented prior to occupation of the development and thereafter be permanently retained. \r\n\r\nTo ensure that the amenity of occupiers of the development site/ surrounding premises is not adversely affected by noise from plant/mechanical installations/ equipment, in accordance with Policies CC11 and CC13 of the Local Plan (2018). \r\n","Condition : 10 - The air conditioning unit shall be positioned above anti-vibration mounts. The unit shall be mounted with proprietary anti-vibration isolators and fan motors are vibration isolated from the casing and adequately silenced. These details shall be implemented prior to occupation of the development and thereafter be permanently retained. \r\n\r\nTo ensure that the amenity of occupiers of the development site/ surrounding premises is not adversely affected by vibration, in accordance with Policies CC11 and CC13 of the Local Plan (2018).\r\n"],"id":"Hammersmith_&_Fulham-P_2026_01409_VAR","application_type":"Householder","pp_id":"14903623","parking_details":null,"url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/01409/VAR","appeal_status":null,"valid_date":"06/05/2026","site_number":"29","application_details":{},"site_name":null,"decision_process":"Delegated","postcode":"SW6 3PJ","last_updated_by":"Northgate M3","centroid":{"lat":51.468502,"lon":-0.206303},"polygon":{"geometries":[{"coordinates":[[[524672.6673766834,175922.67580235103],[524705.3679427977,175919.67653164337],[524704.4673308169,175912.1260885949],[524672.0177448096,175915.1760185511],[524672.6673766834,175922.67580235103]]],"type":"Polygon"}],"type":"geometrycollection"},"appeal_decision":null,"borough":"Hammersmith & Fulham","last_synced":"2026-07-31T02:10:16.543Z","cil_liability":false,"subdivision_of_building":null,"development_type":"Other house holder developments","reference_no_of_permission_being_relied_on":null}