{"date_building_work_completed_under_previous_permission":null,"cil_liability":false,"wgs84_polygon":{"type":"Polygon","coordinates":[[[-0.21709,51.475689],[-0.217008,51.475727],[-0.216703,51.475471],[-0.216782,51.475435],[-0.21709,51.475689]]]},"postcode":"SW6 6EY","ward":"Palace And Hurlingham","appeal_start_date":null,"appeal_decision":null,"valid_date":"04/06/2026","secondary_street_name":null,"centroid_northing":176686.0,"reference_no_of_permission_being_relied_on":null,"actual_commencement_date":null,"last_updated":"2026-09-10T10:20:00.341Z","description":"Erection of a rear extension at second floor level, over part of the existing back addition; erection of a single storey rear extension, to the side and rear of the existing back addition; installation of 2no. air conditioning units and rooflights, on top of the main flat roof at roof level; excavation of the front and part of the rear garden to form lightwells, in connection with the enlargement of the existing basement.","subdivision_of_building":null,"epc_number":null,"url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/01418/HH","borough":"Hammersmith & Fulham","street_name":"Ellerby Street","decision_process":"Delegated","last_synced":"2026-09-11T02:59:40.621Z","last_updated_by":"Northgate M3","date_building_work_started_under_previous_permission":null,"application_type":"Householder","lapsed_date":"09/09/2029","last_date_consultation_comments":"15/07/2026","title_number":["LN171630"],"appeal_status":null,"application_type_full":"Householder planning permission","development_type":"Other house holder developments","decision_target_date":"09/09/2026","lpa_name":"Hammersmith & Fulham","uprn":"34021853","decision_date":"09/09/2026","lpa_app_no":"P/2026/01418/HH","centroid_easting":523934.0,"appeal_decision_date":null,"decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of this planning permission.\r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).","Condition : 2 - The development hereby permitted shall be carried out in complete accordance with the following approved drawings, other than where those details are altered pursuant to the conditions of this planning permission:\r\n\r\nEll22-71 Rev B;\r\nEll22-73 Rev D;\r\nEll22-74 Rev D;\r\nEll22-75 Rev E;\r\nEll22-76 Rev E;\r\nEll22-77 Rev C; \r\nEll22-70 Rev C; \r\nEll22-72 Rev D;  \r\nConstruction Logistics Plan; \r\nConstruction Management Plan; \r\nFlood Risk Assessment.\r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.\r\n","Condition : 3 - The development hereby approved shall be carried out and completed in accordance with the materials details (including colour and finish) specified below:\r\n\r\n- Walls Parapet: Yellow London stock brick to match the existing building in terms of brick and mortar colour and bond pattern. \r\n\r\n- Walls Ground Floor Extension: Zinc Cladding\r\n\r\n- Pod extension: Natural or artificial grey/black slates\r\n\r\n- Dormers face/cheeks: Clad in lead\r\n\r\n- Windows Dormer: Sash Timber frames.\r\n\r\nThe development shall be permanently retained in accordance with the approved details. Any works of making good to existing elevations shall be carried out in materials to match the elevation to which the works relate.  \r\n\r\nTo ensure a satisfactory external appearance, in accordance with Policies DC1, DC4 and DC8 of the Local Plan (2018).\r\n","Condition : 4 - No part of the basement hereby approved shall be occupied or used until the front and rear lightwells have been constructed in accordance with the approved plans and the approved metal grille and walk on glass to the front and rear lightwells have been fitted flush with the surrounding ground level. The metal grille and walk on glass shall be permanently retained in place thereafter. At no time shall railings or any other vertical element be constructed around the lightwell.  \r\n\r\nTo ensure a suitable residential environment for future occupiers and a satisfactory external appearance and to prevent harm to the street scene, in accordance with Policies DC1, DC4, DC8 and DC11 of the Local Plan (2018) and Key Principles BL1, BL2 and BL3 of the Planning Guidance Supplementary Planning Document (2018).\r\n","Condition : 5 - Prior to first use, the window at second floor level in the west elevation as shown on Dwg No. ELL22-77 Rev C shall be fitted with obscure glass to a minimum level of obscurity equivalent to Pilkington Texture Glass Level 3 and shall be fixed shut up to a height of 1.7m above the finished floor level.  The window shall thereafter be permanently retained in this form.  \r\n\r\nTo protect the amenities of adjoining occupiers in terms of privacy and overlooking in accordance with Policy HO11 of the Local Plan (2018).\r\n","Condition : 6 - No water tanks, water tank enclosures or other structures (excluding solar panels and air source heat pumps) shall be erected upon the roof  of the extensions hereby permitted.   \r\n\r\nIt is considered that such structures would seriously detract from the appearance of the building, contrary to Policies DC4 and DC8 of the Local Plan (2018).","Condition : 7 - The development shall be carried out and completed in full accordance with the details contained within the approved Flood Risk Assessment by Roxburgh Construction dated Aug 2026 and the Construction Method Statement by Roxburgh Construction, Ref: 007 dated May 2026.\r\n\r\nNo part of the development shall be used or occupied until all flood prevention and mitigation measures have been installed in accordance with the submitted details and the development shall be permanently retained in this form and maintained as necessary thereafter. \r\n\r\nTo limit the impact on flood risk and mitigate the susceptibility of the development to flooding in accordance with Policies CC2, CC3 and CC4 of the Local Plan (2018).\r\n","Condition : 8 - The development shall be carried out and completed in full accordance with the details contained within the approved Construction Logistics Plan, Rev 2 by by Roxburgh Construction dated May 2026. Thereafter, all construction activities shall be undertaken in accordance with the approved Construction Logistics Plan, which shall be implemented and maintained throughout the construction phase of the development unless otherwise agreed in writing by the Local Planning Authority.\r\n\r\nTo minimise the impacts of construction-related vehicle movements and facilitate sustainable construction travel to the site in accordance with policies T1 and T6 of the Local Plan (2018).\r\n","Condition : 9 - All works proposed in the vicinity of trees must be in accordance with BS5837:2012 and the hereby approved Tree Survey, Arboricultural Impact Assessment and Arboricultural Method Statement by ROAV Group, dated May 2026.\r\n\r\nTo preserve the health of the trees within and in the vicinity of the site and their contribution to the visual amenity of the surrounding area, including the Bishop's Park Conservation Area, in accordance with Policies DC8 and OS5 of the Local Plan (2018).\r\n","Condition : 10 - The extended basement hereby approved shall not be converted to use as a separate dwelling and shall only be used in connection with, and incidental to, the use of the remainder of the application property as a single dwellinghouse.\r\n\r\nThe use of the basement accommodation as a self-contained unit, separate from the use of the remainder of the application property as a single dwellinghouse, would raise materially different planning considerations that the Council would wish to consider at that time, and to minimise flood risk to occupiers, in accordance with Policies DC1, HO4, HO5 and HO11 of the Local Plan (2018)","Condition : 11 - The external sound level emitted from plant, machinery or equipment at the\r\ndevelopment hereby approved shall be lower than the lowest existing background\r\nsound level by at least 10dBA in order to prevent any adverse impact. \r\n\r\nThe assessment shall be made in accordance with BS4142:2014 at the nearest and/or most affected noise sensitive premises, with all machinery operating together at maximum capacity.\r\n\r\nTo ensure that the amenity of occupiers of the development site/\r\nsurrounding premises is not adversely affected by noise from plant/mechanical\r\ninstallations/ equipment, in accordance with Policies CC11 and CC13 of the Local\r\nPlan (2018).","Condition : 12 - Prior to use, machinery, plant or equipment, at the development shall be\r\nmounted with proprietary anti-vibration isolators and fan motors shall be vibration\r\nisolated from the casing and adequately silenced and maintained as such.\r\n\r\nTo ensure that the amenity of occupiers of the development site/ surrounding\r\npremises is not adversely affected by vibration, in accordance with Policies CC11 and\r\nCC13 of the Local Plan (2018).\r\n"],"site_number":"22","bo_system":"Northgate M3","status":"Approved","site_name":null,"decision":"Approved","polygon":{"type":"geometrycollection","geometries":[{"coordinates":[[[523918.267965114,176698.97728326346],[523923.8674022563,176703.3272789946],[523945.76746192394,176675.37808407555],[523940.3927432226,176671.20212933433],[523918.267965114,176698.97728326346]]],"type":"Polygon"}]},"centroid":{"lon":-0.216869,"lat":51.475569},"actual_completion_date":null,"pp_id":"14972464","decision_agency":"Borough","parking_details":null,"locality":"London","id":"Hammersmith_&_Fulham-P_2026_01418_HH","application_details":{"total_gia_gained":225,"no_additional_bathrooms":3,"no_additional_bedrooms":1,"intended_completion_date":"07/2027","intended_commencement_date":"07/2026"}}