{"uprn":"34011043","ward":"Coningham","epc_number":null,"description":"Removal of conditions 4 (terrace screening), 11 (Indoor Air Quality) and 12 (Local Air Quality Building Emissions) of planning permission ref: 2025/02344/FUL granted 15th December 2025 for the 'Erection of a rear roof extension; erection of a rear extension at second floor level over part of the existing back addition; erection of a single storey rear extension, to the side and rear of the existing back addition; installation of 3no rooflights in the front roofslope and 1no rooflight above the main flat roof at roof level; erection of obscure glazed screens in connection with the formation of a roof terrace at third floor level to the rear elevation, on top of the proposed second floor rear back addition; alterations to the roof of ground floor rear back addition; de-conversion of the existing building from 3no self-contained flats into a single family dwellinghouse'.","centroid_easting":522233.0,"decision_date":"18/08/2026","street_name":"Davisville Road","last_synced":"2026-08-19T01:59:24.461Z","locality":"London","status":"Approved","date_building_work_started_under_previous_permission":null,"application_type_full":"Removal/Variation of a condition","lpa_name":"Hammersmith & Fulham","decision_target_date":"18/08/2026","lpa_app_no":"P/2026/01773/VAR","title_number":null,"decision":"Approved","last_updated":"2026-08-19T01:10:31.551Z","appeal_start_date":null,"actual_commencement_date":null,"bo_system":"Northgate M3","secondary_street_name":null,"decision_agency":"Borough","last_date_consultation_comments":"10/08/2026","appeal_decision_date":null,"actual_completion_date":null,"centroid_northing":179661.0,"wgs84_polygon":{"type":"Polygon","coordinates":[[[-0.240514,51.502697],[-0.240216,51.502635],[-0.240195,51.502676],[-0.240503,51.502737],[-0.240514,51.502697]]]},"date_building_work_completed_under_previous_permission":null,"lapsed_date":"17/08/2029","decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of the original planning permission 2025/02344/FUL granted 15th December 2025.\r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).\r\n","Condition : 2 - The development shall be carried out and completed in accordance with the following approved drawings; other than where those details are altered pursuant to the conditions of this planning permission:\r\n\r\n-SP-07 REV A\r\n-SP-08 REV A\r\n-SP-09 REV A\r\n-SP-14 REV A\r\n-Proposed elevations received 09.06.2026\r\n-Proposed plans received 25.03.2026\r\n-FLOOD RISK ASSESSMENT: SuDS, RIVER, RESERVOIR AND SURFACE WATER, 39 Davisville Road, London, W12 9SH Submitted 03/09/2025\r\n\r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.\r\n","Condition : 3 - The development hereby approved shall be carried out and completed in accordance with the materials details (including colour and finish) specified below:\r\n\r\n- Walls - London Stock Brick to match existing\r\n- Windows - Timber framed to front; upvc to rear\r\n- Roof -  Match Existing with Tiles for the mansard. The flat roof will be GRP membrane.\r\n\r\nThe development shall be permanently retained in accordance with the approved details. Any works of making good to existing elevations shall be carried out in materials to match the elevation to which the works relate.\r\n\r\nTo ensure a satisfactory external appearance, in accordance with Policies DC1 and DC4 of the Local Plan (2018).\r\n","Condition : 4 - Free text condition","Condition : 5 - No external air-conditioning units, ventilation fans, extraction equipment, flues or other plant equipment and associated external pipework or ducting shall be fitted to the exterior of the building/front elevation/rear elevation unless otherwise shown on the approved drawings.\r\n\r\nTo ensure a satisfactory external appearance and to prevent harm to the amenities of the occupiers of neighbouring residential properties, in accordance with Policies DC1, DC2, DC4 and HO11 of the Local Plan (2018\r\n","Condition : 6 - The development shall be carried out and completed in full accordance with the details contained within the approved Flood Risk Assessment [FLOOD RISK ASSESSMENT: SuDS, RIVER, RESERVOIR AND SURFACE WATER39 Davisville Road, London W12 9SH Submitted 03/09/2025]. Notwithstanding the contents of approved FRA, the flood prevention and mitigation measures for this development shall include water efficient fixtures/fittings and appliances where these are installed in the kitchen and bathroom. \r\n\r\nNo part of the development shall be used or occupied until all flood prevention and mitigation measures have been installed in accordance with the submitted details and the development shall be permanently retained in this form and maintained as necessary thereafter.\r\n","Condition : 7 - No part of any roof of the ground floor rear extensions hereby approved shall be used as a roof terrace or other form of open amenity space. No alterations shall be carried out; nor planters or other chattels placed on the roof. No railings or other means of enclosure shall be erected on the roof, and no alterations shall be carried out to the property to form access onto the roof. \r\n\r\nThe use of the roof as a terrace would increase the likelihood of harm to the existing residential amenities of the occupiers of neighbouring properties as a result of overlooking, noise and disturbance, contrary to Policies HO11 and CC11 of the Local Plan (2018).\r\n","Condition : 8 - Prior to commencement of the development hereby approved, a Construction Logistics Plan shall be submitted to, and approved in writing by, the Council. The Construction Logistics Plan should seek to minimise the impact of construction traffic on nearby roads and restrict construction trips to off peak hours only. Details shall include, but not be limited to,  the numbers, size and routes of construction vehicles, loading and unloading of construction materials and whether the suspension of any on-street car parking bays would be necessary. Approved details shall be implemented throughout the project period.\r\n \r\nTo ensure that construction works do not adversely impact on the operation of the public highway, in accordance with Policies T1 and T7 of the Local Plan (2018).\r\n\r\n[details approved under application ref. 2026/00125/DET]\r\n","Condition : 9 - Prior to commencement of above ground works in the development hereby permitted, a Ventilation Strategy Report to mitigate the impact of existing poor air quality for the self-contained dwellinghouse (Use Class C3) shall be submitted to and approved in writing by the Local Planning Authority. This is applicable to all residential floors where Council 2030 WHO aligned Annual Mean Air Quality Targets for Nitrogen Dioxide (NO2) - 10ug/m-3, Particulate (PM10) -15 ug/m-3 and Particulate (PM2.5) - 5 ug/m-3 are exceeded and where current and future predicted pollutant concentrations are within 5% of these limits. The report shall include the following information:\r\n1.\tDetails and locations of the ventilation intake locations at rear roof level on the rear elevations of all residential floors. \r\n2.\tDetails and locations of ventilation extracts, to demonstrate that they are located a minimum of 2 metres away from the air ventilation intakes on all residential floors, to minimise the potential for the recirculation of extract air through the supply air ventilation intake in accordance with paragraph 8.9 part 'C' of Building Standards, Supporting Guidance, Domestic Ventilation, 2nd Edition, The Scottish Government, 2017.\r\n3.\tDetails of the independently tested mechanical ventilation system with Nitrogen Dioxide (NO2) and Particulate Matter (PM2.5, PM10) filtration with air intakes on the rear elevation to remove airborne pollutants. The filtration system shall have a minimum efficiency of 90% in the removal of Nitrogen Oxides/Dioxides, Particulate Matter (PM2.5, PM10) in accordance with BS EN ISO 10121-1:2014 and BS EN ISO 16890:2016.\r\n4.\tDetails and locations of restricted opening windows (maximum 200mm for emergency purge ventilation only) for all habitable rooms (Bedrooms, Living Rooms, Study) on all residential floors.\r\n\r\nThe whole system shall be designed to prevent summer overheating and minimise energy usage. The maintenance and cleaning of the systems shall be undertak","Condition : 10 - Prior to occupation of the development hereby permitted, details of a post installation compliance report including photographic confirmation of the mitigation measures as detailed in the approved ventilation strategy as required by condition 9 to mitigate the impact of existing poor air quality shall be submitted to and approved in writing by the Local Planning Authority. The report shall be produced by an accredited Chartered Building Surveyor (MRICS). Approved details shall be fully implemented prior to the occupation/use of the development and thereafter permanently retained and maintained.\r\n\r\nTo reduce the potential adverse air quality impacts in accordance with Policies CC10 of the Local Plan 2018.\r\n","Condition : 11 - Free Text condition","Condition : 12 - Free Text condition","Condition : 13 - Prior to occupation of the development hereby permitted, (including manufacturer specification, installation/commissioning certificates and photographic confirmation) of the installed Waste Water Heat Recovery System (WWHRS) in all the four bathrooms of the self-contained dwellinghouse (Use Class C3) shall be submitted to and approved in writing by the Local Planning Authority. Approved details shall be fully implemented prior to the occupation/use of the development and thereafter permanently retained and maintained.\r\n\r\nTo reduce the potential adverse air quality impacts in accordance with Policies CC10 of the Local Plan (2018).\r\n"],"id":"Hammersmith_&_Fulham-P_2026_01773_VAR","application_type":"All Other","pp_id":"15007857","parking_details":null,"url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/01773/VAR","appeal_status":null,"valid_date":"17/06/2026","site_number":"39","application_details":{},"site_name":null,"decision_process":"Delegated","postcode":"W12 9SH","last_updated_by":"Planning Portal ingest","centroid":{"lat":51.502676,"lon":-0.24032},"polygon":{"geometries":[{"coordinates":[[[522219.41748597345,179663.02444655233],[522240.2679338673,179656.62468567147],[522241.66765450564,179661.22471650311],[522220.11754930456,179667.52532286738],[522219.41748597345,179663.02444655233]]],"type":"Polygon"}],"type":"geometrycollection"},"appeal_decision":null,"borough":"Hammersmith & Fulham","cil_liability":false,"subdivision_of_building":null,"development_type":"Minor dwellings","reference_no_of_permission_being_relied_on":null}