{"polygon":{"geometries":[{"coordinates":[[[525538.3671476933,176501.62591921038],[525541.1672918893,176496.0257916812],[525568.0173643804,176509.72655408393],[525565.9673251328,176515.8759259219],[525538.3671476933,176501.62591921038]]],"type":"Polygon"}],"type":"geometrycollection"},"site_number":"31","appeal_decision_date":null,"ward":"Parsons Green And Sandford","appeal_decision":null,"appeal_start_date":null,"epc_number":null,"borough":"Hammersmith & Fulham","title_number":["LN216249"],"valid_date":"12/08/2026","status":"Approved","decision_process":"Delegated","secondary_street_name":null,"date_building_work_completed_under_previous_permission":null,"reference_no_of_permission_being_relied_on":null,"last_updated":"2026-10-28T17:10:00.539Z","decision_target_date":"27/10/2026","street_name":"Perrymead Street","postcode":"SW6 3SN","site_name":null,"lpa_app_no":"P/2026/01997/HH","development_type":"Other house holder developments","locality":"London","application_type_full":"Householder planning & demolition in a conservation area","wgs84_polygon":{"coordinates":[[[-0.193845,51.473559],[-0.193807,51.473508],[-0.193415,51.473625],[-0.193443,51.473681],[-0.193845,51.473559]]],"type":"Polygon"},"bo_system":"Northgate M3","url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/01997/HH","actual_completion_date":null,"application_type":"Householder","decision":"Approved","decision_date":"28/10/2026","date_building_work_started_under_previous_permission":null,"appeal_status":null,"centroid_easting":525552.0,"lpa_name":"Hammersmith & Fulham","decision_agency":"Borough","last_updated_by":"Northgate M3","last_synced":"2026-10-29T02:48:36.097Z","lapsed_date":"21/10/2029","description":"Erection of a rear extension at first-floor level above a replacement ground-floor rear extension; enlargement of the existing basement beneath the garden; alterations to the existing front lightwell; infilling of existing rooflights and installation of two new rooflights in the front roofslope; alterations to fenestration including alterations to the rear dormer and the installation of a Juliet balcony; installation of an air conditioning enclosure above the roof of the ground-floor rear addition; alterations to the rear fenestration at ground-floor level; erection of a bin store within the front garden; and replacement of all existing windows with double-glazed timber-framed windows.","last_date_consultation_comments":"16/09/2026","application_details":{"no_additional_bedrooms":0,"total_gia_gained":60,"no_additional_bathrooms":0,"intended_commencement_date":"10/2026","intended_completion_date":"10/2027"},"pp_id":"15101030","actual_commencement_date":null,"uprn":"34067415","centroid_northing":176507.0,"subdivision_of_building":null,"centroid":{"lat":51.473604,"lon":-0.193647},"parking_details":null,"id":"Hammersmith_&_Fulham-P_2026_01997_HH","cil_liability":false,"decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of this planning permission.\r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).","Condition : 2 - The development hereby permitted shall be carried out in complete accordance with the following approved drawings, other than where those details are altered pursuant to the conditions of this planning permission:\r\n\r\n146/200\r\n146/201\r\n146/202\r\n146/203\r\n146/204A\r\n146/205A\r\n146/206A\r\n146/207A\r\n146/208A\r\n146/209A\r\n146/210\r\n146/211\r\n146/212\r\n146/213A\r\n146/250\r\nA01\r\nQuietstone Light Acoustic Panel Technical Datasheet, prepared by Quietstone Innovative Acoustics ( received 22.10.2026).\r\nNoise Impact Assessment Report (Mechanical Plant), Sound Licensing Ltd, Rev. 2.0, dated 14/10/2026.\r\nFRA\r\nCMS\r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.\r\n","Condition : 3 - The development hereby approved shall be carried out and completed in accordance with the materials (including colour and finish) specified on the drawings hereby approved. The development shall be permanently retained in accordance with the approved details. Any works of making good to existing elevations shall be carried out in materials to match the elevation to which the works relate.  \r\n\r\nTo ensure a satisfactory external appearance, in accordance with Policies DC1, DC4 and DC8 of the Local Plan (2018).","Condition : 4 - The metal grille to the existing front lightwell, as shown on the approved plan (Ref 146/202), shall be installed flush with the surrounding ground level and shall thereafter be permanently retained in accordance with the approved plans. At no time shall railings or any other vertical element be installed around the lightwell.\r\n\r\nTo ensure a suitable residential environment for future occupiers and a satisfactory external appearance and to prevent harm to the street scene, in accordance with Policies DC1, DC4, DC8 and DC11 of the Local Plan (2018) and Key Principles BL1, BL2 and BL3 of the Planning Guidance Supplementary Planning Document (2018).\r\n","Condition : 5 - No piling shall take place until a Piling Method Statement.(detailing the depth and type of piling to be undertaken and the methodology by which such piling will be carried out, including measures to prevent and minimise the potential for damage to subsurface sewerage\r\ninfrastructure, and the programme for the works) and piling layout plan including all Thames Water wastewater assets, the local topography and clearance between the face of the pile to the face of a pipe has been submitted to and approved in writing by the local planning authority in consultation with Thames Water. \r\n\r\nAny piling must be undertaken in accordance with the terms of the approved piling method statement and piling layout plan. \r\n\r\nTo ensure the protection of Thames Water infrastructure in line with Policies CC5 and CC6 of the Local Plan (2018","Condition : 6 - The balustrade of the Juliet balcony to the main rear roof extension ref 146/213A hereby permitted shall be fixed flush with the rear elevation of the building at the same time as the associated doors are installed. The doors to the Juliet balconies shall open inwards only. The doors and balustrades shall be permanently retained in this form for the lifetime of the development. \r\n\r\nTo ensure a satisfactory external appearance and to protect the amenities of adjoining occupiers in terms of privacy and overlooking, in accordance with Policies DC1, DC4, [DC8] and HO11 of the Local Plan (2018).\r\n","Condition : 7 - No water tanks, water tank enclosures or other structures (excluding solar panels and air source heat pumps) shall be erected upon the roofs of the extensions hereby permitted. \r\n\r\nIt is considered that such structures would seriously detract from the appearance of the building, contrary to Policies DC4 and DC8 of the Local Plan (2018).\r\n","Condition : 8 - The development shall be carried out and completed in full accordance with the details contained within the approved Flood Risk Assessment [ref number/date]. No part of the development shall be used or occupied until all flood prevention and mitigation measures have been installed in accordance with the submitted details and the development shall be permanently retained in this form and maintained as necessary thereafter.  [    ] needs updating or deleting as applicable\r\n\r\nTo limit the impact on flood risk and mitigate the susceptibility of the development to flooding in accordance with Policies CC2, CC3 and CC4 of the Local Plan (2018).\r\n","Condition : 9 - The basement extension hereby approved shall not be converted to use as a separate dwelling and shall only be used in connection with, and incidental to, the use of the remainder of the application property as a single dwellinghouse.  The use of the basement accommodation as a self-contained unit, separate from the use of the remainder of the application property as a single dwellinghouse, would raise materially different planning considerations that the Council would wish to consider at that time in accordance with Policies DC1, HO4, HO5 and HO11 of the Local Plan (2018).  ","Condition : 10 - No part of any roof of the  ground and first floor extensions hereby approved shall be used as a roof terrace or other form of open amenity space. No alterations shall be carried out; nor planters or other chattels placed on the roofs. No railings or other means of enclosure shall be erected on the roofs, and no alterations shall be carried out to the property to form access onto the roofs.The use of the roofs as a terrace would increase the likelihood of harm to the existing residential amenities of the occupiers of neighbouring properties as a result of overlooking, noise and disturbance, contrary to Policies HO11 and CC11 of the Local Plan (2018).  ","Condition : 11 - Prior to use, machinery, plant or equipment, extract/ ventilation system and ducting at the development shall be mounted with proprietary anti-vibration isolators and fan motors shall be vibration isolated from the casing and adequately silenced and maintained as such. \r\n\r\nTo ensure that the amenity of occupiers of the development site/ surrounding premises is not adversely affected by vibration, in accordance with Policies CC11 and CC13 of the Local Plan 2018.   \r\n","Condition : 12 - The external sound level emitted from plant, machinery or equipment at the development hereby approved shall be lower than the lowest existing background sound level by at least 5dBA in order to prevent any adverse impact. The assessment shall be made in accordance with BS4142:2014 at the nearest and/or most affected noise sensitive premises, with all machinery operating together at maximum capacity.\r\n\r\n\r\nTo ensure that the amenity of occupiers of the development site/ surrounding premises is not adversely affected by noise from plant/mechanical installations/ equipment, in accordance with Policies CC11 and CC13 of the Local Plan 2018\r\n"]}