{"status":"Approved","decision":"Approved","valid_date":"03/09/2026","decision_target_date":"11/11/2026","last_synced":"2026-11-13T02:15:52.460Z","centroid_northing":176577.0,"development_type":"Other house holder developments","actual_completion_date":null,"decision_conditions":["Condition : 1 - The development hereby permitted shall not commence later than the expiration of 3 years beginning with the date of this planning permission.\r\n\r\nCondition required to be imposed by section 91(1)(a) of the Town and Country Planning Act 1990 (as amended by section 51 of the Planning and Compulsory Purchase Act 2004).","Condition : 2 - The development hereby permitted shall be carried out in complete accordance with the following approved drawings, other than where those details are altered pursuant to the conditions of this planning permission:\r\n\r\nReceived 06/11/2026 - \r\n1703/305-2;\r\n1703/306-2;\r\n1703/307-2;\r\n\r\nReceived 02/09/2026 -\r\n1703/301-2;\r\n1703/302-2;\r\n1703/303-2;\r\n1703/304-2;\r\n1703/308-2;\r\n1703/309-2; \r\nFLOOD RISK ASSESSMENT; \r\nWINDOW SCHEDULE & SPECIFICATION SHEET.\r\n\r\nTo ensure full compliance with the planning application hereby approved and to prevent harm arising through deviations from the approved plans.\r\n","Condition : 3 - The development hereby approved shall be carried out and completed in accordance with the materials (including colour and finish) specified on the drawings hereby approved. \r\n\r\nThe development shall be permanently retained in accordance with the approved details. Any works of making good to existing elevations shall be carried out in materials to match the elevation to which the works relate.\r\n\r\nTo ensure a satisfactory external appearance, in accordance with Policies DC1, DC4 and DC8 of the Local Plan (2018).\r\n","Condition : 4 - The windows hereby approved in the northeastern side elevation at first and second floor levels as shown on Dwg No. 1703 / 306-2 shall be fitted with obscure glass to a minimum level of obscurity equivalent to Pilkington Texture Glass Level 3, and shall be fixed shut up to a height of 1.7m above the finished floor level. The window shall thereafter be permanently retained in this form.  \r\n\r\nTo protect the amenities of adjoining occupiers in terms of privacy and overlooking in accordance with Policy HO11 of the Local Plan (2018).\r\n","Condition : 5 - The balustrade of the Juliet balconies at the rear of the roof extension and rear of the back addition at first floor level as shown on Dwg No. 1703 / 305-2, hereby permitted shall be fixed flush with the rear elevation of the building at the same time as the associated doors are installed. The doors to the Juliet balconies shall open inwards only. The doors and balustrades shall be permanently retained in this form for the lifetime of the development.  \r\n\r\nTo ensure a satisfactory external appearance and to protect the amenities of adjoining occupiers in terms of privacy and overlooking, in accordance with Policies DC1, DC4, DC8 and HO11 of the Local Plan (2018).\r\n","Condition : 6 - No part of any roof of the rear roof extension, pod and ground floor rear extension hereby approved shall be used as a roof terrace or other form of open amenity space. No alterations shall be carried out; nor planters or other chattels placed on the roofs. No railings or other means of enclosure shall be erected on the roofs, and no alterations shall be carried out to the property to form access onto the roofs.\r\n\r\nThe use of the roof as a terrace would increase the likelihood of harm to the existing residential amenities of the occupiers of neighbouring properties as a result of overlooking, noise and disturbance, contrary to Policies HO11 and CC11 of the Local Plan (2018).   \r\n","Condition : 7 - No water tanks, water tank enclosures or other structures (excluding solar panels and air source heat pumps) shall be erected upon the roof of the extensions hereby permitted.  \r\n\r\nIt is considered that such structures would seriously detract from the appearance of the building, contrary to Policies DC4 and DC8 of the Local Plan (2018).\r\n","Condition : 8 - The development shall be carried out and completed in full accordance with the details contained within the approved Flood Risk Assessment by Icon Architects dated September  2026. No part of the development shall be used or occupied until all flood prevention and mitigation measures have been installed in accordance with the submitted details and the development shall be permanently retained in this form and maintained as necessary thereafter.  \r\n\r\nTo limit the impact on flood risk and mitigate the susceptibility of the development to flooding in accordance with Policies CC2, CC3 and CC4 of the Local Plan (2018).\r\n"],"lpa_name":"Hammersmith & Fulham","date_building_work_completed_under_previous_permission":null,"cil_liability":true,"pp_id":"15197690","last_updated":"2026-11-12T08:00:03.940Z","parking_details":null,"lapsed_date":"11/11/2029","title_number":null,"locality":"London","url_planning_app":"https://property.lbhf.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/02284/HH","last_date_consultation_comments":"14/10/2026","wgs84_polygon":{"type":"Polygon","coordinates":[[[-0.219087,51.474757],[-0.219017,51.47479],[-0.218814,51.474615],[-0.218823,51.474611],[-0.218753,51.474551],[-0.21873,51.474518],[-0.218791,51.47449],[-0.218824,51.474518],[-0.218958,51.47463],[-0.219087,51.474757]]]},"application_type_full":"Householder planning permission","ward":"Palace And Hurlingham","bo_system":"Northgate M3","appeal_decision_date":null,"decision_date":"11/11/2026","centroid":{"lat":51.47462,"lon":-0.218907},"lpa_app_no":"P/2026/02284/HH","actual_commencement_date":null,"site_name":null,"secondary_street_name":null,"id":"Hammersmith_&_Fulham-P_2026_02284_HH","uprn":"34022823","centroid_easting":523795.0,"decision_agency":"Borough","decision_process":"Delegated","street_name":"Ellerby Street","subdivision_of_building":null,"epc_number":null,"site_number":"68","reference_no_of_permission_being_relied_on":null,"polygon":{"geometries":[{"coordinates":[[[523782.11855516944,176591.9279230968],[523786.9186330682,176595.72754520277],[523801.4685434089,176576.62736698287],[523800.86852705706,176576.12765523657],[523805.8683759596,176569.62772300246],[523807.56870804296,176566.02729827416],[523803.4188321881,176562.777546792],[523801.0682853419,176565.8280832044],[523791.41829955083,176578.0776229148],[523782.11855516944,176591.9279230968]]],"type":"Polygon"}],"type":"geometrycollection"},"appeal_decision":null,"date_building_work_started_under_previous_permission":null,"last_updated_by":"Northgate M3","borough":"Hammersmith & Fulham","application_details":{"intended_completion_date":"12/2027","total_gia_gained":97,"no_additional_bathrooms":4,"intended_commencement_date":"11/2026","no_additional_bedrooms":2},"appeal_start_date":null,"description":"Erection of a front and rear roof extension, involving an increase in the ridge height, and including the  installation of French doors and a Juliet balcony to the proposed rear roof extension; erection of a rear extension at second floor level, over part of the existing back addition; erection of a single storey rear extension, to the side and rear of the existing back addition, including rear-facing bi-fold doors and side-facing pitched rooflights; installation of French doors and a Juliet balcony to replace existing window to the rear elevation at first floor level; repositioning of the existing window to the side elevation at first floor level; installation of a new window to the side return at ground floor level; and replacement of all existing single-glazed windows with double-glazed units to match the neighbouring property.","appeal_status":null,"postcode":"SW6 6EZ","application_type":"Householder"}