{"actual_completion_date":null,"appeal_start_date":null,"application_type_full":"Householder planning permission","decision_conditions":["Condition : 1 - The development hereby permitted shall begin not later than three years from the date of this decision.\r\n\r\nReason: In order to comply with Section 91 of the Town and Country Planning Act 1990, as amended by Section 51 of the Planning and Compulsory Purchase Act 2004.","Condition : 2 - The development hereby permitted shall be carried out in accordance with the following approved plans and specifications:  01 (Rev A), 02 (Rev A), 03 (Rev A), 04 (Rev A), 05 (Rev A), 06 (Rev A) Received:  15 July 2026,  BP1, PP-14921064v1 Received:  11 May 2026.\r\n\r\nReason: In order to ensure the development is carried out in accordance with the planning permission.","Condition : 3 - The materials to be used in the construction of the external surfaces of the development hereby permitted shall match those used in the existing building, unless otherwise shown on the approved plans.\r\n\r\nReason: In order to safeguard the appearance of the area.","Condition : 4 - No additional windows or openings shall be formed in the rear and side elevations of the development hereby permitted.\r\n\r\nReason: In order to protect neighbours' privacy.","Condition : 5 - a) The cumulative measured or calculated rating level of noise emitted from the re-installed air conditioning unit hereby permitted shall be 10dB(A) below the existing background noise level at all times that the plant is operating.  The measured or calculated noise levels shall be determined at the boundary of the nearest ground floor noise sensitive premises or one metre from the facade of the nearest first floor (or higher) noise sensitive premises, in accordance with the latest British Standard 4142.  An alternative position for assessment/ measurement may be used to allow ease of access, this must be shown on a map and noise propagation calculations detailed to show how the design criteria are achieved.  \r\n\r\nb) The plant shall be isolated on adequate proprietary anti-vibration mounts to prevent the structural transmission of vibration and regenerated noise within adjacent or adjoining premises, and these shall be so maintained thereafter.  \r\n\r\nc) Following the re-installation of the air conditioning unit hereby permitted, a post completion noise assessment shall be submitted for the approval of the Local Planning Authority that demonstrates the actual measured rating level of plant operating under normal conditions.  All measurements shall be made in accordance with the methodology of BS4142:  2014 (Methods for rating and assessing industrial and commercial sound) and/ or its subsequent amendments.  The post completion report shall be both completed and submitted to the Local Planning Authority within 28 days of the re-installation of the air conditioning unit hereby permitted in the location within the house's rear garden required by the approved proposed drawings.  If the plant fails to meet the specified standard, remedial measures shall be put in place immediately and a further noise assessment shall be carried out.  This shall be repeated until the noise assessment demonstrates that the required standard has been complied with.  Once achieved, the plant sh"],"decision":"Approved","appeal_decision":null,"valid_date":"15/05/2026","description":"Erection of a single storey rear infill extension to the house and re-installation of its air conditioning unit in the rear garden.  ","status":"Approved","last_updated_by":"Planning Portal ingest","site_number":"77","cil_liability":false,"decision_process":null,"development_type":"Other house holder developments","subdivision_of_building":null,"centroid_northing":178304.0,"last_updated":"2026-08-28T01:08:20.859Z","lapsed_date":"26/08/2029","bo_system":"Northgate M3","centroid":{"lat":51.490654,"lon":-0.252421},"parking_details":null,"url_planning_app":"https://planningandbuilding.hounslow.gov.uk/NECSWS/ES/Presentation/Planning/OnlinePlanning/OnlinePlanningOverview?applicationNumber=P/2026/1411","pp_id":"14921064","locality":"London","reference_no_of_permission_being_relied_on":null,"uprn":"100021582473","ward":"Chiswick Homefields","last_synced":"2026-08-28T02:02:52.245Z","application_details":{"total_gia_gained":6.34,"no_additional_bathrooms":0,"no_additional_bedrooms":0,"intended_completion_date":"12/2026","intended_commencement_date":"08/2026"},"street_name":"Cranbrook Road","decision_agency":"Borough","appeal_decision_date":null,"site_name":null,"last_date_consultation_comments":"11/06/2026","secondary_street_name":null,"lpa_name":"Hounslow","title_number":["unregistered"],"epc_number":null,"decision_date":"27/08/2026","wgs84_polygon":{"coordinates":[[[-0.252399,51.490681],[-0.252366,51.490617],[-0.252359,51.490606],[-0.252427,51.49059],[-0.252433,51.490601],[-0.252491,51.490708],[-0.252503,51.49073],[-0.252513,51.49075],[-0.252444,51.490764],[-0.252414,51.490707],[-0.252407,51.490694],[-0.252399,51.490681]]],"type":"Polygon"},"date_building_work_started_under_previous_permission":null,"decision_target_date":"27/08/2026","postcode":"W4 2LJ","appeal_status":null,"polygon":{"geometries":[{"coordinates":[[[521426.468235068,178307.02639203655],[521428.9687846704,178299.927277776],[521429.46839183127,178298.72641229111],[521424.7681956792,178296.8273457744],[521424.3188194521,178298.07725410705],[521420.0513878417,178309.88299615704],[521419.16648925294,178312.32639899495],[521418.3686529654,178314.52709656712],[521423.1685511922,178316.17707830638],[521425.3978057373,178309.93824260676],[521425.9293308081,178308.4477371532],[521426.468235068,178307.02639203655]]],"type":"Polygon"}],"type":"geometrycollection"},"centroid_easting":521425.0,"date_building_work_completed_under_previous_permission":null,"borough":"Hounslow","id":"Hounslow-P_2026_1411","application_type":"Householder","lpa_app_no":"P/2026/1411","actual_commencement_date":null}